Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Table of Contents

...

Location of the Single Footing Settings Dialog

It is also available in the Singular basic Single Footing auxiliary toolbar that appears after the single basic footing command is run.

...

It can also be accessed by clicking on the Reinforced Concrete/Foundation-Floor /Single Foundation Footing/Single Foundation Footing Settings icon.

...

General Settings

...

Specifications

ExplainedDescription

Basic name

Footing ID

Image RemovedImage Added

 

It is the name of the singular foundationsingle footing. The letter T is placed in front of the number entered here and the name of the singular foundation single footing is created and written on the foundation footing in the plan. The number is increased according to the order in which the foundations footings are drawn (such as T1, T2, T3 ....). The singular single base names can be changed later using the Name Object command. The name index does not have to be T. Different indices can be used for renaming.

Outer frame color

Image RemovedImage Added

The color of the individual base outline (s). The color palette is scrolled by clicking and holding down the left mouse button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. Pen thickness is not noticeable on the screen. The drawing is valid when drawn on paper.

Inner frame color

Image RemovedImage Added

 

It is the color of the frame around the columnsingle footing. The color palette is scrolled by clicking and holding down the left mouse button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. Pen thickness is not noticeable on the screen. The drawing is valid when drawn on paper.

Link

Connection line color

Image RemovedImage Added

 

It is the color of the lines connecting the inner frame and outer frame corner points. The color palette is scrolled by clicking and holding down the left mouse button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. Pen thickness is not noticeable on the screen. The drawing is valid when drawn on paper. If the connection lines are trapezoidal (if the height at the edge is different from the height at the column level), it is drawn. In cases where the two heights are equal, the connection line is not drawn because the basic will be rectangular.

Line type

Linetype

Image RemovedImage Added

The line type of the line forming the pile single footing is selected in the plan. Clicking the down arrow buttons to the right of the boxes opens the list of line types. From this list, the desired line type is selected by clicking with the left mouse button.

Frame distance

Image RemovedImage Added

 

A frame surrounding the column can be drawn on a single foundation footing where the column rests on a single foundationfooting. The distance of the frame from the column face is entered in this box. If the frame is required to be drawn, check the option "There is an inner frame". If this option is not checked, the frame will not be drawn.

Size

Dim X

Image RemovedImage Added

 

It is the dimension of the single foundation footing parallel to the X dimension of the column resting on it. Column X dimension is the column dimension in the column axis direction. The column axis is the arrow drawn from the column node. If the "Draw column axesaxis" option is selected from Settings/General Settings/ General Settings Preferences in the classic menu, Settings/Settings/ General Settings / General Settings Preferences in the ribbon menu, it appears on the column on the screen.

Size Y

Image RemovedImage Added

 

It is the dimension of the single foundation footing parallel to the Y dimension of the column resting on it. The column Y dimension is the dimension perpendicular to the column axis.

Wacky

Delta X

Image Removed Image Added

 

It is the offset alignment of the single foundation footing in the column local X-axis direction. If the offset delta X is zero, the left edge of the singular foundation single footing coincides with the left edge of the column. If positive, the left edge of the singular foundation single footing shifts to the left by the value entered from the left edge of the column. If negative, the left edge of the singular foundation single footing shifts to the right by the value entered from the column left edge. The directions should be considered according to the local axis of the column.

Wacky

Delta Y

Image Removed Image Added

It is the misalignment alignment of the single foundation footing in the column local Y axis direction. If the offset delta Y is zero, the upper edge of the single foundation footing coincides with the upper edge of the column. If it is positive, the upper edge of the single foundation footing will slide up by the value entered from the upper edge of the column. If negative, the upper edge of the single foundation footing shifts down by the value entered from the upper edge of the column. The directions should be considered according to the local axis of the column.

Height at

the

edge

Image RemovedImage Added

 

It is the vertical (in z direction) height of the single foundation footing at the edge. If single foundations footings with trapezoidal cross-section are to be made, the foundation footing height at the edge should be smaller than the foundation footing height at the column level. For single foundations footings with rectangular cross section, the heights at the side and at the column level should be equal.

On the edge of the column

Image Removed

Height at column edge

Image Added

 

It is the vertical (in z direction) height of the single foundation footing at the level of the column face. If single foundations footings with trapezoidal cross-section are to be made, the foundation footing height at the column level should be greater than the foundation footing height at the edge. For single foundations footings with rectangular cross section, the heights at the side and at the column level should be equal.

Kot

Elevation

Image RemovedImage Added

 

The single foundation footing is higher than the floor story floor. When the elevation is zero, the upper surface of the single foundation footing coincides with the floor base. If a negative value is entered in the level section, the base floor slides down from the base. Positive values ​​shift the foundation footing up from the floor base. If the individual foundation footing level is changed, the column level on the foundation footing must also be changed accordingly. If not replaced, the column will not sit on the foundationfooting.

Advanced Settings

...

Specifications

Explained

Name Letter Height, Color, Font

Image Removed

ID text

Image Added

 

The height of the pile single footing name text is entered. The color box is slid over the color palette that is opened by clicking with the left mouse button and holding down the button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. If the button just below is clicked, the Font Settings dialog opens. From this dialog, the Column Header Name Text, font is set. Articles are written horizontally.

Size Font Height, Color, Font

Image Removed

Dimension text

Image Added

 

The height of the pile single footing dimension text is entered. The color box is slid over the color palette that is opened by clicking with the left mouse button and holding down the button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. If the button just below is clicked, the Font Settings dialog opens. From this dialog, the Column Header Size Text, font is set. Articles are written horizontally.

Text X/Text Y

Image RemovedImage Added

X and Y coordinates are entered according to the upper left corner of the column heading of the Pile Name single footing ID text. Text If the X value is positive, the name text will move to the left, if it is negative, it will move to the right. Text scrolls up if the Y value is positive, and down if it is negative.

Size

Dim X/

Size

Dim Y

Image RemovedImage Added

X and Y coordinates are entered according to the upper right corner of the column heading of the Pile Dimension single footing dimension text. If the dimension X value is positive, the dimension text shifts to the left, if it is negative, it shifts to the right. If the dimension Y value is positive, the dimension text will scroll up, and if it is negative, it will scroll down.

Materiel

Image Removed

 

 

Material

Image Added

The material to be covered on the foundations footings in the solid model is selected. The base is covered with the selected material and displayed as such in the solid model. Click on the down arrow button with the left mouse button. The appropriate material is selected from the opened material list. If there is no defined item, the list is blank. Adding material is done from the dialog that opens by clicking Settings/Materials line in the classic menu and Settings/Settings/Materials in the ribbon menu.

Actual tissue

Texture world length

Image RemovedImage Added

 

 

Tissue Text length is entered. For example; If 1 meter is entered, the selected material texture is taken as 1 meter and covered on the selected object. Considering that the texture is in the form of a square, the object surfaces are covered with 1x1 textures arranged side by side.

Building Components

...

Add Building Components : Assigns the building materials defined for detailed building components metrics to the object.

...

Following are the lines that appear in the Proportion list according to the individual basic object and material size.

Singular single Basic

Measure

Listed

Explanation

Constant

Independent

The fixed measure used will be used exactly as the amount.

Length

Independent

It means that the length measure found while defining the material will be used exactly as the length value.

environment

It means that the length of the material will be found by multiplying the circumference of the single foundation footing with the length measure found while defining the material.

Height

It means that the length of the material will be found by multiplying the length measurement found when defining the material and the height of the single foundationfooting.

Domain

Independent

It means that the area measure found while defining the material will be used exactly as the amount.

Volume

Independent

The volume measurement found when defining the material will be used exactly as the volume value.

Volume

It means that the volume measurement found when defining the material will be used by multiplying the floor volume.

Number

Independent

The number measure found while defining the material will be used exactly as the material number.

Number

The number measure found while defining the material will be used exactly as the material number.