Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Note

The condition ∑Mdev> = 0.75Mo must be met in reinforced concrete carrier structural systems with unidirectional gear floor with DTS = 1, 1a, 2, 2a, 3a or 4a.

...

The condition of ∑Mdev / M0> = 0.75 must be met in reinforced concrete carrier structural systems with unidirectional gear floor with earthquake design class (DTS) 2.

According to article 4.3.4.6 of TBDY , ductility level should be provided in mixed carrier structural systems (4.3).

                                                              ∑ M DEV ≥ 0.75 M o                                                       (4.3)

 

Possible solutions:

  • A curtain Shearwall / curtain shearwall group can be added to the carrier structural system until the 4.3 condition is met.

  • Solution can be made by choosing high ductility level. ( A14 or A15 )

  • Different flooring type can be selected.

...