For drawing angled beams continuously;
In the General Reinforced Concrete Parameters Reinforcement Settings dialog, the angle value must be entered in the "Always accept beams with small angle differenceBeams/panels continuous if angle is less than" line. (A maximum of 30 degrees can be entered.)
If the viewing direction of the beams is different, the direction of view must be made the same with the "Change Modify/Beam-Foundation Footing/ Determine object Set entity direction" command.