Structural Tab
...
Specifications | Explained |
---|---|
Structural material | Select the static material to be used in the dome element from the list. Static material can be defined as a reinforced concrete element under Materials in Building Tree. |
Dead load | Fixed external loads are entered, except for the reinforced concrete weight of the dome, which consists of thickness. |
Live load | The moving load value to be used in the calculation of the dome is entered. |
Finite element width | Enter the maximum finite element width to be taken as basis in shell calculation. The program analyzes shells by dividing them into trapezoidal form finite elements. Finite element width is automatically adjusted according to the shell shape, provided that it does not exceed the value entered in this row. |
...
The parameters available in the component selection dialog are:
...
In the usage section
No modification: The amount of material to be assigned for the object in question is marked when it is desired to be used in the size that was previously specified in the material definition.
...