You can adjust the steel wind column settings from the Hall settings dialog Settings tab.

Table of Contents

Location of Steel Wind Column Settings

Select the hall where you want to change the steel wind column settings and click the right mouse button. Click the Properties line from the right click menu that opens.

Image RemovedImage RemovedImage AddedImage Added

General Settings Tab

Section loading and element misalignment can be set in the General Settings tab.

one

Load Section

By accessing the ready section library, a list of American and European finished rolling sections is reached and a selection is made from the list.

2nd

Layout Type

It provides adjustment of 9 different offset in its placement on the column axis.

3

Kot

It refers to the height of the lower end of the column to be placed from the floor floor on which it is modeled.

4

Height

Refers to the length of the column.

View Tab

In the steel column settings View sub-tab, the color, material and plan label settings of the element are made on the plan and perspective screen.

Image RemovedImage Added

Curvature Tab

To model a curved column in any axis, switch to the Curvature sub-tab. Enter the curvature value of the column in the radius of curvature section, select the horizontal or vertical states of the curvature, the direction is determined by entering the value '+' or '-'.