Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Table of Contents

...

Full Strength Bolted

...

End Plate

...

Connections

  • It consists of 3 different types.

  • The factors determining the behavior of the combination; beam cross-section reaching to flow yield under bending effect, frontal end plate reaching to flow yield under bending effect, flowing yielding of column panel area, breaking rupture of bolts under tensile effect, breaking rupture bolts under shear effect.

  • The controls listed above are applied automatically and detailed explanations and references and parameters used in the account are given in the report.

  • The YDKT method must be selected to report these combinations used in the connection of moment transfer frame elements carrying earthquake loads together with TBDY 2018 and ÇYTHE 2018.

...

  • There are conditions that must be met in order to be used in 3 types of frames with high ductility level or limited moment transferspecial moment frames or intermediate moment frames. These conditions are given in TBDY 2018 Table 9B.1 according to the ductility level. ideCAD Statik AISC 358-16 6.3. ideCAD Static automatically checks and reports these conditions.

  • Plastic hinges cause inelastic bending deformations in the joining beam and column panel area in the joints with butt end plate. Therefore, strong column, strong joint and weak beam design are considered as philosophy. For this reason, the length of the plastic hinge and its distance from the column face are especially checked in the table below.

...

...

End Plate Joint Design Steps

  • The strength of the frontal end plate joint connection is determined by the assumption that the tensile force of the bolts in one head flange is controlled by the crushing rupture limit state under the pressure compressive force in the other.

  • If there is no axial load on the joint, the total tensile and compressive forces are equal and opposite in both headsflanges, so that the total force creates a force pair.

  • The row of bolts farthest from the pressure head compression flange is considered as the region subject to the greatest tensile force, and while the inverse triangular force distribution is considered for ease of calculation, and a ductile joint is calculated on a parabolic distribution according to the plastic force distribution assumption.

  • The bending Flexural strength of the frontal end plate and column head flange is determined by yield line analysis. The flow yield line method can be calculated by the energy or virtual work method.

    Image Removed

...

  • Strong column, strong joint and weak beam are used to calculate the forces on the bolt and to find the required bolt strength. According to this assumption, while the column, panel region and beam exhibit inelastic behavior, the joint and column show elastic behavior. For this reason, it is necessary to design suitable for the thick plate for the frontal end plate. In thick plate behavior, the force in the bolts is the static moment at the center of the pressure head.

    Image Removed

    comprensive flange.

    • The equations used are as follows:

...

Boundary Situations to Check

Effective Force

Connection Element

Reference

Do not Pull

Bolt (Pull)

a

Do not Pull

Plate (Bending)

b

Do not Pull

Column head (Tilt)

c

Do not Pull

Beam body (Tensile)

d

Do not Pull

Column body (Tensile)

is

Do not Pull

Title - Plate welding

f

Do not Pull

Body-Plate welding

g

Horizontal Cut

Column body (Cutting)

h

Pressure

Beam head (Pressure)

j

Pressure

Beam head welding

to

Pressure

Column body

l

Vertical Cutting

Body - Plate welding

m

Vertical Cutting

Bolt (Cutting)

n

Vertical Cutting

Bolt crush

p

...