Specifications |
---|
Thickness Zone thickness is entered. Zone thickness is the value measured from the story floor upwards. If the thickness of the zone is increased, the zone becomes thicker upwards. |
Elevation Zone elevation is entered. When the elevation is zero, the lower surface of the zone coincides with the story base. If a positive value is entered, the zone rises up from the story floor, if a negative value is entered, it falls under the story floor. |
Color The zone is the color of the border lines. When the color box is clicked, the appropriate color is selected from the window that opens. |
Use plasters for area calculation If the use plasters for area calculation option is selected, the plaster calculation becomes active. If it is automatically marked, the area between the wall plaster and the wall is deducted from the zone area while calculating the zone area and the area value found is written on the zone. If the percentage is marked, while calculating the zone area, the zone area is deducted as the percentage of the value written in the "Percentage" line and this value is written on the zone. If the thickness is marked, while calculating the zone area, the plaster thickness is taken into account as the value entered in this line and the area between the plaster and the wall is deducted from the zone area. If the use plasters for area calculation option is not selected, plaster thicknesses are not taken into account in the zone area calculation. |
Material The material to be used on the upper, lower and other surfaces of the zone is selected from the list. Surfaces are covered with the selected material and displayed as such in renderings. Texture length is entered into the world length. For example; If 1 is entered, the selected material texture is taken as 1 meter and covered on the relevant walls. The angle is the angle of the texture. Offset the U and V shifting. The motion value in the x and y plane is entered. With U and V mirroring, the texture is symmetrical with respect to the y and x planes. By selecting the single material option, the material selected in "Top material" is used on all surfaces of the zone. |
Use composite material Composite materials allow the zone to be drawn in a different material view in the section. If checked, it allows the use of materials defined in the "Composite Material" editor. After the row is marked, one of the composite materials in the list below is selected with the left mouse button. Changes the view of the zone in section according to the selected composite material. |
Reversed composite material If marked, the materials used in the zone are reversed. When the section is taken, the top hatching in the zone section area appears at the bottom, the bottom hatch at the top. |
Trimmed area drawing Using the "Trim to roof" command, it is marked if it is desired to show the section created with the zone and roof on the plan. If it is not desired, it is not marked. Color and line type determine the visual settings of the intersection on the plan. |
Fill zone region It gives color to the zone. |
Zone area calculation When the zone is placed, if there is a wall, stair or column object in the zone, it is used to subtract the total area of these objects from the total area of the zone while calculating the zone area. If Consider Columns is checked, ZoneArea Net = Zone Area - Area of Columns Within the Zone If Consider stairs is checked, ZoneArea Net = Zone Area - Area of Stairs Within the Zone If the wall is marked, ZoneArea Net = Area I Area - Area of Walls within the Zone One or more of the options can be marked at the same time. |
...
Text Tab
...
Specifications |
---|
Building nameStructure ID This line is used for the definition of the space zone in the quantities created according to DIN277 and II BV standards. Name of the building is entered. |
Location tagZone ID It is the name that will appear in the building components of the spacezone. |
Site Zone name Enter the name of the location zone here (living room, kitchen, etc.). Enter the site zone name in the box, click the OK button and the dialog is closed. The site zone name entered is written on the relevant site zone in the plan. |
Floor/Ceiling/Wall Enter the name of the coatings (parquet, ceramic, paint etc.) in the area and the area belonging to the sitezone. |
Height Distance between poststexts The distance between the two lines is entered in the space zone text block written on the spacezone. |
PainAngle The angle of the location zone text written on the site zone is entered.Label text |
Write ID If it is checked, the location label zone id is shown in the plan. Font Text height: The height of the Mahal tag zone id text is adjusted. |
Write name If checked, the name of the site zone is shown in the plan. Font Text height: The height of the zone name of the place text is adjusted. |
Cover writing Write coating material If it is marked, the area covering text is shown in the plan. Lettering Text height: The height of the inscription covering the mahal zone coating text is adjusted. |
Field writingWrite area If marked, the site zone area is shown in the plan. Font Text height: The height of the field zone area text is adjusted. |
Reports Tab
...
Specifications |
---|
DIN 277 - Space class The option is marked for whatever purpose the location will be used for. Options, respectively; HFN1 is sitting and rest, HFN2 office, HFN3 production and research, HFN4 warehouse and sales, HFN5 education and culture, HFN6 medical, NNF other, VF round trip, FF function. |
ALSO 277 - Dear tipi One of the options a-top and all edges closed, b-top closed, open edge exists, c-top open options are marked or automatic selection is marked and the program is automatically found. |
II BV domain account The "Area calculation factor" containing II BV metrics is entered. |
Adding to DIN 277 meter When the option is selected, the space is not taken into consideration in DIN 277 meters. |
Inclusion in BV footage When the option is selected, the site is not taken into consideration in the II BV meter. |
Adding to volume calculation When the option is selected, the space volume is not taken into consideration in DIN 277 and II BV quantities. |
Inclusion in TAKS report When the option is selected, the location is not taken into account in the TAKS report. |
Inclusion in KAKS report When the option is selected, the location is not taken into account in the KAKS report. |
...