Specifications |
---|
Structure ID This line is used for the definition of the zone in the quantities created according to DIN277 and II BV standards. Name of the building is entered. |
Zone ID It is the name that will appear in the building components of the zone. |
Zone name Enter the name of the zone here (living room, kitchen, etc.). Enter the zone name in the box, click the OK button and the dialog is closed. The zone name entered is written on the relevant zone in the plan. |
Floor/Ceiling/Wall Enter the name of the coatings (parquet, ceramic, paint etc.) in the area and the area belonging to the zone. |
Distance between texts The distance between the two lines is entered in the zone text block written on the zone. |
Angle The angle of the zone text written on the zone is entered. |
Write ID If it is checked, the zone id is shown in the plan. Text height: The height of the zone id text is adjusted. |
Write name If checked, the name of the zone is shown in the plan. Text height: The height of the zone name text is adjusted. |
Write coating material If it is marked, the area covering text is shown in the plan. Text height: The height of the zone coating text is adjusted. |
Write area If marked, the zone area is shown in the plan. Text height: The height of the zone area text is adjusted. |
Reports Tab
...
Specifications |
---|
DIN 277 - Space classZone category The option is marked for whatever purpose the location zone will be used for. Options, respectively; HFN1 is sitting residential and restrecreation, HFN2 office, HFN3 production and research, HFN4 warehouse storage and sales, HFN5 education and culture, HFN6 medical treatment, NNF other, VF round triptraffic, FF function. |
ALSO DIN 277 - Dear tipiZone type One of the options a-top and all edges sides are closed, b-top is closed, open edge side exists, c-top is open options are marked or automatic selection is marked and the program is automatically found. |
II BV domain account The "Area calculation factor" - area calculation The area account factor containing II BV metrics is entered. |
Adding to DIN 277 meterreports When the option is selected, the space zone is not taken into consideration in DIN 277 metersreports. |
Inclusion in II BV footagereports When the option is selected, the site zone is not taken into consideration in the II BV meterreports. |
Adding to volume calculation Volume calculations When the option is selected, the space zone volume is not taken into consideration in DIN 277 and II BV quantitiesreports. Inclusion in TAKS report |
Built-up area ratio reports When the option is selected, the location zone is not taken into account in the TAKS report. Inclusion in KAKS report build-up area ratio reports |
Floor area ratio reports When the option is selected, the location zone is not taken into account in the KAKS reportfloor area ratio reports. |
Units Tab
...
Specifications | ||||||||
---|---|---|---|---|---|---|---|---|
Basic Base units One of the selections is activated by clicking the left mouse button on the job.
Number of households
| ||||||||
Digit count It determines how many digits will be shown after the comma. The desired number is selected from the list. For example, if 2 is selected, units will be shown as two digits after the comma. If 0 is selected, units will not be shown after the comma. |
...