Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Specifications

Structure ID

This line is used for the definition of the zone in the quantities created according to DIN277 and II BV standards. Name of the building is entered.

Zone ID

It is the name that will appear in the building components of the zone.

Zone name

Enter the name of the zone here (living room, kitchen, etc.). Enter the zone name in the box, click the OK button and the dialog is closed. The zone name entered is written on the relevant zone in the plan.

Floor/Ceiling/Wall

Enter the name of the coatings (parquet, ceramic, paint etc.) in the area and the area belonging to the zone.

Distance between texts

The distance between the two lines is entered in the zone text block written on the zone.

Angle

The angle of the zone text written on the zone is entered.

Write ID

If it is checked, the zone id is shown in the plan.

Text height: The height of the zone id text is adjusted.
Text color: The color of the zone id text is adjusted.
Text font: The font of the zone id written on the zone is selected.

Write name

If checked, the name of the zone is shown in the plan.

Text height: The height of the zone name text is adjusted.
Text color: The color of the zone name text is adjusted.
Text font: The font of the zone name written on the zone is selected.

Write coating material

If it is marked, the area covering text is shown in the plan.

Text height: The height of the zone coating text is adjusted.
Text color: The color of the zone coating text is adjusted.
Text font: The font of the zone coating text written on the zone is selected.

Write area

If marked, the zone area is shown in the plan.

Text height: The height of the zone area text is adjusted.
Text color: The color of the zone area text is adjusted.
Text font: The font of the zone area written on the zone is selected.

Reports Tab

...

Specifications

DIN 277 - Space classZone category

Image RemovedImage Added

The option is marked for whatever purpose the location zone will be used for. Options, respectively; HFN1 is sitting residential and restrecreation, HFN2 office, HFN3 production and research, HFN4 warehouse storage and sales, HFN5 education and culture, HFN6 medical treatment, NNF other, VF round triptraffic, FF function.

ALSO DIN 277 - Dear tipiZone type

Image RemovedImage Added

One of the options a-top and all edges sides are closed, b-top is closed, open edge side exists, c-top is open options are marked or automatic selection is marked and the program is automatically found.

II BV domain account

Image Removed

The "Area calculation factor" - area calculation

Image Added

The area account factor containing II BV metrics is entered.

Adding to DIN 277 meterreports

Image RemovedImage Added

When the option is selected, the space zone is not taken into consideration in DIN 277 metersreports.

Inclusion in II BV footagereports

Image RemovedImage Added

When the option is selected, the site zone is not taken into consideration in the II BV meterreports.

Adding to volume calculation

Image Removed

Volume calculations

Image Added

When the option is selected, the space zone volume is not taken into consideration in DIN 277 and II BV quantitiesreports.

Inclusion in TAKS report

Image Removed

Built-up area ratio reports

Image Added

When the option is selected, the location zone is not taken into account in the TAKS report.

Inclusion in KAKS report

Image Removed

build-up area ratio reports

Floor area ratio reports

Image Added

When the option is selected, the location zone is not taken into account in the KAKS reportfloor area ratio reports.

Units Tab

...

Specifications

Basic Base units

Image RemovedImage Added

One of the selections is activated by clicking the left mouse button on the job.

Expand
titleDahası

Number of households

Image Removed
Moreover

Meter: If checked, the unit of information text will be meters.
Centimeter: If checked, the unit of the callout will be centimeter.
Millimeter: If checked, the unit of callout will be millimeter.
Fit : If checked, the unit of callout will be fit.
Inch : If checked, the unit of callout will be inches.

Digit count

Image Added

It determines how many digits will be shown after the comma. The desired number is selected from the list. For example, if 2 is selected, units will be shown as two digits after the comma. If 0 is selected, units will not be shown after the comma.

...