Location of Single Footing Parameters Dialog

Ribbon menu Analysis and Design tab Design Parameters title under Curtain parameters by clicking on the command Curtain Parameters can be found in the dialogue.

...

Single Footing Parameters

It determines with parameters which criteria the program will comply with in reinforced concrete design and reinforcement placement stage.

...

Specifications

Specifications

Concrete cover

Image Added

It is the distance from the center of gravity of the reinforcement in the single foundation to the outer face of the concrete.

Mine. pursantaj 

Image Added

It is the parameter that determines the minimum reinforcement to be placed on a single foundation. Under no circumstances can the reinforcement be less than the limit specified by this parameter.

Max. reinforcement range

Image Added

In the program, the range of the reinforcement to be placed on a single foundation is selected so that it is not more than the value specified in this parameter.

Min. reinforcement range

Image Added

In the program, the range of the reinforcement to be placed on a single foundation is selected so that it is not less than the value specified in this parameter.

Use column moments in the calculus

Image Added

The default state is checked. If it is not checked, only normal forces are taken into account in the foundation calculation from the effects of the column caused by vertical and earthquake loads from the superstructure. Column moments are not taken into account. In this case, the information on Mx and My values ​​is not displayed under the heading Column Loads Under Basement in the Single Baseline report.

Use earthquake normal forces in the calculator

Image Added