Table of Contents |
---|
...
Location of Retaining Wall Parameters Dialog
Ribbon menu Analysis and Design tab Design Parameters title under Retaining Wall Parameters by clicking on the command Retaining Wall Parameters can be found in the dialogue.
...
Retaining Wall Parameters
It determines with parameters which criteria the program will comply with in reinforced concrete design and reinforcement placement stage.
...
Specifications |
---|
Concrete cover It is the distance from the center of gravity of the reinforcement to the outer face of the concrete. |
Min. tensile reinforcement pursuit In the tensile zone, give the minimum percentage value to be used in the reinforcement calculation. The entered value is multiplied by the cross-sectional area and the reinforcement selection is made in a way that is not less than the result. |
Min. tensile reinforcement range In the tensile zone, give the smallest possible distance between two reinforcement bars. This value is taken into consideration in the selection of reinforcement. |
Max. tensile reinforcement range In the tensile zone, give the value of the greatest possible distance between two rebars. This value is taken into consideration in the selection of reinforcement. |
Min. transverse reinforcement pursuit Give the minimum percentage value to be used in horizontal reinforcements. The entered value is multiplied by the cross-sectional area and the reinforcement selection is made in a way that is not less than the result. |
Max. transverse reinforcement range Give the maximum possible distance between two reinforcement bars to be used in horizontal reinforcements. This value is taken into consideration in the selection of reinforcement. |
Min. pressure reinforcement pursuit In the pressure zone, give the minimum percentage value to be used in reinforcement calculation. The entered value is multiplied by the cross-sectional area and the reinforcement selection is made in a way that is not less than the result. |
Min. pressure reinforcement range Give the smallest possible distance between two reinforcing bars in the pressure zone. This value is taken into account in the selection of reinforcement. |
Max. pressure reinforcement range Give the maximum possible distance between two reinforcing bars in the pressure zone. This value is taken into consideration in the selection of reinforcement. |