For any of two earthquake directions perpendicular to each other, discontinuity in lateral strength–extreme weak story irregularity is defined as the story lateral strength is less than 65% of that in the story above. The story strength is the total strength of all seismic-resisting elements sharing the story shear for the direction under consideration.
...