Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Tip
  • As required by Codes, the earthquake calculation is made automatically in every 4 cases by shifting the storey masses by 5%.

Tip

In accordance with Codes, the horizontal earthquake loads are calculated automatically by shifting (+) and (-) 5%.

Info

In modeling accidental torsion, any of the static and dynamic methods that comply with the regulation can be used for analysis. Method selection is controlled by users.

...

İnternational Design Codes

ASCE 7-16 : Application of Accidental Torsion

TSC 2018 : Additional Eccentricity Modelling

...

Horizontal earthquake loads affecting the floor mass center or nodes is shifted by + 5% and -5% of the floor dimension perpendicular to the earthquake direction considered, and earthquake calculation is also made for these cases.

Accidental torsion is a building-code requirement for both regular and irregular structures, since uneven distribution of live-load mass during lateral loading and variation between computed and actual values of structural properties.