Structural system selection , Response modification coefficient, Deflection amplification factor Cdand Overstrength factor are is controlled by user.

Info

Wizard the necessary instructions are made by user.

Tip

Design coefficients and factors selected by user in the analysis settings wizard and report results are checked automatically.

...

İnternational International Design Codes

ASCE 7-16 : 12.2 Structural System Selection

TSC 2018 : R and D Coefficients For Seismic Force-Resisting SystemsSYMBOLS
Tp, all = Natural vibration period calculated in the same direction in the structural system.
Tp,top= Natural vibration period calculated in the same direction without taking into account all basement masses including the ground floor in the structural system

...

Notation in ASCE 7-16
Cd = Deflection amplification factor
Ωo = Overstrength factor
R = Response modification coefficient

...

Seismic Force-Resisting System is defined as, the part of the structural system that has been considered in the design to provide the required resistance to the seismic effects. In the Seismic Design Codes, the structural systems consisting of structural elements (column, beam, shearwall, brace) and Modification Coefficients of these structural seismic force-resisting systems are defined. Modification Coefficients vary according to the structural system type and ductility level. Response modification coefficients are defined in Seismic design Codes.