...
Click the Edit Concrete Calculation Line icon.
Select a calculation line from the defined slab.
The Slab Concrete Reinforcement Axis Parameters dialog will open.
In this dialog, working and reinforcement type of the selected concrete calculation lines are selected.
Make the changes you want and click the OK button to close the dialog.
According to the changes you make, your concrete calculation line will change.
Slab Concrete Reinforcement Axis Parameters Dialogue
Axis Type Tab
...
Options | |||||
---|---|---|---|---|---|
Straight + bent-up reinforcement When selected, it indicates that the processed reinforcement axis will be designed as a reinforcement type consisting of flat and pillars. The reinforcement will be laid flat and in the form of a pile. | |||||
Under straight reinforcement When selected, it indicates that the axis of the processed reinforcement will be straight reinforcement at the bottom. The reinforcement will be laid in the form of flat reinforcement at the bottom. | |||||
Special cantilever reinforcement It is the type of reinforcement to be used for cantilever slabs. Indicates that the processed reinforcement axis will be designed as cantilever reinforcement. | |||||
Upper straight reinforcement When selected, it indicates that the axis of the processed reinforcement will be straight reinforcement on top. The reinforcement will be laid as one straight reinforcement at the top. | |||||
Upper+under straight reinforcement When selected, it indicates that the processed reinforcement axis will be designed as straight reinforcement type at the bottom and top. The reinforcement will be laid as straight reinforcement at the bottom and at the top. | |||||
Left valid distance It determines how many meters distance the reinforcement will be placed on the left of the calculation lines used. Changing the value written here affects the number of slab reinforcements. For example, the valid distance is 345 cm and the slab reinforcement is fi8/36. The number of reinforcement is 345 cm/36=9.58; means that 10 pieces of 8' reinforcement will be used on the left. | |||||
Right valid distance It determines the distance of the reinforcement to be placed on the right of the calculation lines used. Changing the value written here affects the number of slab reinforcements. For example, the valid distance is 345 cm and the slab reinforcement is fi8/36. The number of reinforcement is 345 cm/36=9.58; means that 10 pieces of 8' reinforcement will be used on the left. | |||||
2 way short The plate is a double-sided plate and the concrete calculation line is in the short side direction of the plate. (Llong/Lsh<2)
| |||||
1 way short The plate is a single-direction plate and the concrete calculation line is in the short side direction of the plate. (Llong/Lshort≥2 or balcony, landing floor)
| |||||
2 way long The plate is a double-sided plate and the concrete calculation line is located on the long side of the plate. (Llong/Lsh<2)
| |||||
1 way long The plate is a single-direction plate and the concrete calculation line is located on the long side of the plate. (Llong/Lshort≥2 or balcony, landing floor)
| |||||
Override clear length for thickness control When the option is selected and the value is entered, the calculation gap is made according to the entered value in the slab thickness control. |