The design Design strength control of the steel column named PL007 is made done under the most unfavorable internal forces as a result of the general analysis determined according to TBDY 2018 9.3.1.3. The material and section information of the column is are as follows:

Steel material: S355 Fy =355 N/mm 2 Fu =510 N/mm 2

...

It should be checked whether the cap flange width/thickness and body web height/thickness values ​​of the column cross-section exceed the λhd value given in Table 9.3 .

...

Mathinline
body$$ \normalsize P_u_c =1933.958$$
As a result of the analysis, the column design point is taken from the cross section.

Mathinline
body--uriencoded--$$ \normalsize C_a =\frac %7B1933.958%7D%7B0.90(355*21.8)%7D =0.278>0.125 $$

...

Mathinline
body--uriencoded--$$ \normalsize 24.57< 48.46 >1.49√\frac %7B200000 %7D%7B355%7D=35.37$$
koşulu sağlar.

The Check of the cross-section condition check is made according to the TBDY 2018 Table 9.3 in the steel column report and is summarized in tabular form.

...

Axial Force Strength

The calculation of the bending flexural buckling boundary state about the X-axis is as follows:

...

Mathinline
body$$ \normalsize F_c_r_x = 344.73$$
MPa

The calculation of the bending flexural buckling boundary state about the Y-axis is as follows:

...

Mathinline
body$$ \normalsize P_d =ΦP_n=0.9*6334.96=5701.46$$
kN

...

Flexural Moment Strength

Mathinline
body$$ \normalsize L_b =3780$$
mm

...

In this case, the characteristic bending moment strength should be calculated by ÇYTHYE Equation 9.3. Cb , moment correction coefficient , the lateral-torsional buckling modification factor, used in this calculation is calculated determined automatically according to the moment values ​​read on the relevant column.

...

Shear Force Strength

According to article section 10.2.1(a) of ÇYTHYE in I-cross section with double symmetry axes,

...

Axial Capacity Control

In addition to the axial pressure capacity we calculated for design the design elements under combined effects above, the axial tensile force must also be controlled in accordance with TBDY 9.3.1.3. The point to be considered in this control check is that the horizontal earthquake effects obtained from the analysis must be increased by D, the excess strength coefficientoverstrenght factor.

...