Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Punching Control is controlled in accordance with TBDY 7.11.8 , TBDY 7.11.9 , TBDY 7.11.10, TBDY 7.11.11, TBDY 7.11.12, TBDY 7.11.13. In the picture below, there is an example of the floor punching control report made with ideCAD StaticStructural.

...

Punching control As specified in TBDY 7.11.8 , with the assumption that shear stresses in the slab change linearly with respect to the geometric center of the punch perimeter in the loading direction, the punching perimeter on the slab (u p will be made by calculating the idealized distribution of the shear stresses acting on the ), .

...