According to Table 12.3-1, the calculation of the relative storey drifts is made according to the Equivalent Earthquake Load Method, taking into account the + - 5% eccentricity effects. While linear dynamic analysis are used in the earthquake calculation of the building, Equivalent Earthquake Load Method is used in1a and 1b type irregularity control.
...