A c = Gross cross-sectional area of the column or curtain end zone
ΣA g= The sum of the cross-sectional areas of the
structural system elements operating as a curtain parallel to the earthquake direction considered at any floor ΣA p= Total of the plan areas of all floors of the building
E = Earthquake effect
f ctd= Concrete design tensile strength
f ck = characteristic cylinder compressive strength of concrete
G = constant load effect
N dm =The largest of the axial pressure forces calculated under the joint effect of vertical loads and earthquake loads (taking into account the live load reduction coefficients defined for live loads in TS 498)
Q= Live load effect
V t = Total earthquake load acting on the building according to Section 4 (base shear force)
...
Requirements for the control of 7.6.1.2 and 7.6.1.3 are given in the Curtain Arm Thickness line under the Group Wall Dimension and Reinforcement Conditions heading of the Preliminary Information report of the Curtain Group . The picture below shows an example of the Curtain Group Preliminary Information report.
...
.
...