Tip |
---|
|
Tip |
---|
|
Tip |
---|
|
Tip |
---|
|
...
ICONS
D = Strength Excess Coefficient
f ck = Characteristic cylinder compressive strength of concrete
f yk = Characteristic yield strength of longitudinal reinforcement
H w = Total curtain height measured from the top of the foundation or the ground floor slab
H cr = Curtain critical height
l w = Curtain or tie-beam curtain part length in plan
( M p ) t = f ck at the base section of the curtain, f ykand the moment capacity calculated by considering the strength increase of the steel
( M d ) t = The moment calculated under the combined effect of the vertical loads and earthquake loads multiplied by the load coefficients at the base section of the wall
R = The load-bearing system behavior coefficient
V d = The vertical loads and earthquake loads multiplied by the load coefficients Shear force calculated under the joint effect
V e = Shear force based on transverse reinforcement calculation at column, beam, junction area and curtain
β v = Shear force dynamic magnification coefficient in curtain
...
Design shear forces of polygonal walls with H w / l w ≤ 2.0 according to TBDY Article 7.6.6.3 are taken equal to shear forces calculated according to TBDY Section 4 . The shear force value calculated under the combined effect of the vertical loads and the earthquake loads increased with the Resistance Excess Coefficient D is used as the design shear force, V e . These shear forces are calculated in the center of gravity of the polygon walls and distributed to the polygon curtain arms in accordance with the shear force direction, taking into account the shear areas. This check is done for all loading combinations and the most unfavorable condition is taken into account.
...