How does ideCAD control increased structural height limits for Steel Eccentrically Braced Frames, Steel Special Concentrically Braced Frames, and Special Reinforced Concrete Shear Walls according to ASCE 7-16?

...

Tip
  • The software controls the Increased structural height limit automatically according to ASCE 7-16 12.2.5.4.

...

Increased Structural Height Limit for Steel Eccentrically Braced Frames, Steel Special Concentrically Braced Frames, Steel Buckling-Restrained Braced Frames, Steel Special Plate Shear Walls, and Special Reinforced Concrete Shear Walls

The limits on structural height, hn, are given in Table 12.2-1, shown below.

It has permitted to be increased from 160 ft (50 m) to 240 ft (75 m) for structures assigned to Seismic Design Categories D or E and from 100 ft (30 m) to 160 ft (50 m) for structures assigned to Seismic Design Category F, on condition that the seismic force-resisting systems are limited to steel eccentrically braced frames, steel special concentrically braced frames, steel buckling restrained braced frames, steel special plate shear walls, or special reinforced concrete cast-in-place shear walls.

...