How does ideCAD design two-way joist systems (waffle slabs) according to ACI 318-19?

...

Tip
  • Minimum slab thickness over fillers is controlled and reported automatically.

...

Nonprestressed two-way joist systems is are designed according to ACI 8.8.

...

  • Spaced ribs and a top slab are parts of waffle slabs.

  • Minimum width of ribs is 4 in.

  • Overall The overall depth of ribs do does not exceed 3.5 times the minimum width.

  • Clear spacing between ribs is a maximum 30 in.

  • At least one bottom bar in each joist are is continued and anchored to develop fy at the face of supports.

  • To provide slab moment strength requirements, considering Considering load concentrations, a reinforcement area perpendicular to the ribs is designed to provide slab moment strength requirements and is at least the shrinkage and temperature reinforcement area according to 24.4.

...

  • Minimum slab thickness is the greater of one-twelfth the clear distance between ribs and 2 in., if fillers do not complying comply with 8.8.2.1 or removable forms are used.

...