Basis of Design

The design of SMF should be done according to AISC 341-16, in which structural elements are expected to provide significant inelastic deformation capacity through flexural yielding of SMF beams and limited yielding of column panel zones.

System Requirements

Moment Ratio

Columns must be stronger than beams in order to prevent brittle collapse, except for the intended mechanism.

...

Stability Bracing of Beams