Analysis settings that vary depending on the UBC 97 are explained in detail.

UBC 97 Options Tab

...

Specifications

Structural system type

Image Modified

The type of structural system for X and Y direction is selected in accordance with the design of the building.

Response modification coefficient

Image Modified

It is the response modification coefficient value. This row is automatically refreshed when the structural system type is chosen.

Overstrength factor

Image Modified

It is the strength excess coefficient value. This row is automatically refreshed when the structural system type is chosen.

Redundancy factor

Image Modified

It is the redundancy factor value. This row is automatically refreshed when the structural system type is chosen.

ELF Ct parameter

Image Modified

It is the ELF Ct parameter. This row is automatically refreshed when the structural system type is chosen.

Accidental eccentricity ratio

Image Modified

The eccentricity ratio to be used during the analysis is given as a percentage.

Use custom vertical seismic load factor

Image Modified

If checked, the custom vertical seismic load factor which entered in "factor to use (instead of 0.2 SDS)" line is used.

Structural system

Image Modified

If the building block consists of only concrete elements, Concrete; if it consists of only steel elements, Steel; Steel + Concrete option is selected if it consists of concrete and steel elements.

Building Risk Category

Image Modified

Building risk category value is selected from the list according to the purpose of use of the building.

Story drift check

Image Modified

Allowable story drift value is entered.

Response Spectrum Tab

...

Specifications

Spectrum curve

Image Modified

The spectrum curve resulting from the settings is shown.

Function name

Image Modified

The name of the spectrum function.

Spectrum multiplier

Image Modified

Factor of spectrum function.

Soil profile type

Image Modified

Soil profile type is selected for the response spectrum.

Seismic zone factor

Image Modified

Seismic zone factor value is entered for the response spectrum.

Seismic source type

Image Modified

Seismic source type is selected for the response spectrum.

Distance to source [km]

Image Modified

Distance to source value is entered for the response spectrum.

User defined values

Image Modified

If this option is selected, parameters such as Ca, Cv, Na and Nv become active.

Ca/Cv

Image Modified

Seismic coefficient value is entered for the response spectrum.

Na

Image Modified

Near source factor use in the detemination of Ca for the response spectrum.

Nv

Image Modified

Near source factor use in the detemination of Cv for the response spectrum.

...

Next Topic

ASCE7 - 16