Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

For example,

K1, Ground Floor Shear Safety not providedBeam shear safety is not satistied

On beams:

Should V e ≤ 0.85 bd  √ fck

Vd ≤ should be 0.22 fcd bw d (TS 500).

And Ve ≤ must be 0.22 fcd bw d (TS 500)

...

  1. Vr breaking capacity and if the design remains smaller than the cutting shear force. (And must be <Vr)

  2. And if the design exceeds the Vmax, which must be controlled from the shear force as per regulation

Possible Solutions:

  • For cases 1 and 2, the cross section dimensions of the named and solid element can be increased.

  • For case 2, it can increase the transverse (for stirrup selection) reinforcement diameters that can be used for the relevant element in the Reinforcement Selection dialog.

  • Concrete and reinforcement class can be increased for the 1st and 2nd case.

 

...

Symbols

Ac = Column and curtain shearwall cross section area

fck = characteristic cylinder compressive strength of concrete

...