Analysis settings that vary depending on the NSCP 2015 are explained in detail.
NSCP 2015 Options Tab in ideCAD Structural
...
Specifications |
---|
Structural system type per NSCP 2015 The type of structural system for X and Y direction is selected in accordance with the design of the building. |
Response modification coefficient per NSCP 2015 It is the response modification coefficient value. This row is automatically refreshed when the structural system type is chosen. |
Overstrength factor per NSCP 2015 It is the strength excess coefficient value. This row is automatically refreshed when the structural system type is chosen. |
Redundancy factor per NSCP 2015 It is the redundancy factor value. This row is automatically refreshed when the structural system type is chosen. |
ELF Ct parameter per NSCP 2015 It is the ELF Ct parameter. This row is automatically refreshed when the structural system type is chosen. |
Accidental eccentricity ratio per NSCP 2015 The eccentricity ratio to be used during the analysis is given as a percentage. |
Use custom vertical seismic load factor per NSCP 2015 If checked, the custom vertical seismic load factor which entered in "factor to use (instead of 0.2 SDS)" line is used. |
Structural system per NSCP 2015 If the building block consists of only concrete elements, Concrete; if it consists of only steel elements, Steel; Steel + Concrete option is selected if it consists of concrete and steel elements. |
Building Risk Category per NSCP 2015 Building risk category value is selected from the list according to the purpose of use of the building. |
Story drift check per NSCP 2015 Allowable story drift value is entered. |
Response Spectrum Tab in ideCAD Structural for NSCP 2015
...
Specifications |
---|
Spectrum curve per NSCP 2015 The spectrum curve resulting from the settings is shown. |
Function name per NSCP 2015 The name of the spectrum function. |
Spectrum multiplier per NSCP 2015 Factor of spectrum function. |
Soil profile type per NSCP 2015 Soil profile type is selected for the response spectrum. |
Seismic zone factor per NSCP 2015 Seismic zone factor value is entered for the response spectrum. |
Seismic source type per NSCP 2015 Seismic source type is selected for the response spectrum. |
Distance to source [km] per NSCP 2015 Distance to source value is entered for the response spectrum. |
User defined values per NSCP 2015 If this option is selected, parameters such as Ca, Cv, Na and Nv become active. |
Ca/Cv per NSCP 2015 Seismic coefficient value is entered for the response spectrum. |
Na per NSCP 2015 Near source factor use in the detemination of Ca for the response spectrum. |
Nv per NSCP 2015 Near source factor use in the detemination of Cv for the response spectrum. |
...