The distance between the centers of standard, large, and slot holes, s, is not less than 22/3 times the nominal diameter, d, of the fastener. According to AISC 360-16, the distance between centers of standard, oversized, or slotted holes of 3D is preferred. (s ≥ 3d)
This control is done automatically and reported in bolted connections.
...
The distance from the standard hole diameter center to the edge of the element, in any direction, cannot exceed the values given in AISC 360-16 Table J3.4.
The distance from the center of the large or slotted hole to the connected part edge cannot be less than that required for a standard hole to an edge of a connected part plus the applicable increment, C2, from AISC 360-16 Table J3.5.
This control is done automatically and reported in bolted connections.
TABLE J3.4M | |
---|---|
Bolt Diameter, mm | Minimum Edge Distance |
M16 | 22 |
M20 | 26 |
M22 | 28 |
M24 | 30 |
M27 | 34 |
M30 | 38 |
M36 | 48 |
≥ M36 | 1.25d |
TABLE J3.5M | ||||
---|---|---|---|---|
Nominal Diameter of Fastener | Oversized Holes | Slotted Holes | ||
Long Axis Perpendicular to Edge | Long Axis Parallel to Edge | |||
Short Slots | Long Slots | |||
≤ 22 | 2 | 3 | 0.75d | 0 |
24 | 3 | 3 | ||
≥ 27 | 3 | 5 |
Maximum Bolt Spacing and Distance to Edge
...
Note: The points specified in AISC 360-16 J2b.2 for the maximum thickness of the filled welds are not automatically checked.
TABLE J2.3 Minimum Effective Throat of Partial-Joint-Penetration Groove Welds | |
---|---|
Material Thickness of Thinner Part Joined, mm | Minimum Effective Throat, ( mm) |
To 6 inclusive | 3 |
Over 6 to 13 | 5 |
Over 13 to 19 | 6 |
Over 19 to 38 | 8 |
Over 38 to 57 | 10 |
Over 57 to 150 | 13 |
Over 150 | 16 |
TABLE J2.4 | |
---|---|
Material Thickness of Thinner Part Joined, mm | Minimum Effective Throat, ( mm) |
To 6 inclusive | 3 |
Over 6 to 13 | 5 |
Over 13 to 19 | 6 |
Over 19 | 8 |
...
Next Topic