Parametric Limitations on Prequalification for Four-Bolt Unstiffened Connections

Parameter

Maximum
in. (mm)

Minimum
in. (mm)

tbf

3/4 (19)

3/8 (10)

bbf

91/4 (235)

6 (152)

d

55 (1400)

133/4 (349)

tp

21/4 (57)

1/2 (13)

bp

103/4 (273)

7 (178)

g

6 (152)

4 (102)

pfi , pfo

41/4 (114)

11/2 (38)

pb

-

-

...