Parametric Limitations on Prequalification for Four-Bolt Unstiffened Connections | ||
---|---|---|
Parameter | Maximum | Minimum |
tbf | 3/4 (19) | 3/8 (10) |
bbf | 91/4 (235) | 6 (152) |
d | 55 (1400) | 133/4 (349) |
tp | 21/4 (57) | 1/2 (13) |
bp | 103/4 (273) | 7 (178) |
g | 6 (152) | 4 (102) |
pfi , pfo | 41/4 (114) | 11/2 (38) |
pb | - | - |
...