Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Prequalification Limits (AISC 358-16 Table 6.1)

All end-plate moment connection configurations should satisfy these beam and column limitations. Beam and column limitations are given in AISC 358-16 Table 6.1.

Beam span / Beam cross-section height

9144 mm /450 mm=20.32

≥7.0

End plate thickness, tp

32 mm

13≤tp ≤38

End plate width, bp

290 mm

178≤ bp ≤ 273

Horizontal distance between bolts, g

150 mm

83≤g≤152

pfi

60 mm

44≤pfi ≤140

pfo

60 mm

44≤pfo ≤140

Beam depth, db

450 mm

349≤db≤610

Beam flange thickness, tbf

15 mm

10≤tbf ≤19

Beam flange width, bbf

190

152≤bbf ≤229

Column depth

650

≤ 920 mm

Bolt grade

10.9

8.8 - 10.9

Min yield stress of the end plate material

275 MPa

235 /275 / 355 MPa

Flange plate weld

CJP

CJP

STRENGTH CHECKS

...

Bolt diameter

The required bolt diameter, db, for four bolts stiffened end plate connection is checked according to AISC 358-16 §6.8

Muc

821.813 kNm

AISC 358-16 (6.8-3)

Ft

750000 kN/m2

 

ho

 

h1

 

db

 

Required

Available

Ratio

Control

29.825 mm

36 mm

0.829

End Plate Thickness

The required end plate thickness, tb, for four bolts stiffened end plate connection is checked according to AISC 358-16 §6.8

Muc

821.813kNm

AISC 358-16 (6.8-5)

Fyp

275000 kN/m2

 

s

 

Yp

 

Yp

 

tp

 

Required

Available

Ratio

Control

27.327 mm

30 mm

0.911

End Plate Stiffener Thickness

The required stiffener thickness, tb, for four bolts stiffened end plate connection is checked according to AISC 358-16 §6.8

tbw

9 mm

AISC 358-16 (6.8-9)

Fyb

275000 kN/m2

 

Fys

275000 kN/m2

 

ts

12 mm

 

 

 

 

 

Required

Available

Ratio

Control

9 mm

12 mm

0.750

End Plate Stiffener Local Buckling

Stiffener local buckling limit statefor four bolts stiffened end plate connection is checked according to AISC 358-16 §6.8

hs

144 mm

AISC 358-16 (6.8-10)

ts

12 mm

 

E

200000000 kN/m2

 

Fys

275000 kN/m2

 

 

 

 

 

Required

Available

Ratio

Control

12

15.102

0.795

Stiffener to Beam Flange Weld Size

The required end weld sizefor four bolts stiffened end plate connection is checked.

Fys

275000 kN/m2

AISC DG 4-2 nd

3.2.10

ts

12 mm

 

Fe

490000 kN/m2

 

w

 

Required

Available

Ratio

Control

6.35

7.072

0.898

Stiffener to End Plate Weld Size

The required end weld sizefor four bolts stiffened end plate connection is checked.

Fys

275000 kN/m2

AISC DG 4-2 nd

3.2.10

ts

12 mm

 

Fe

490000 kN/m2

 

w

 

Required

Available

Ratio

Control

6.35

7.072

0.898

Bolt Shear

...

Check

The shear limit state of end plate bolts is checked according to AISC 360-16.

Ab

AISC 358-16 6.8.11

Fn

Rn

ΦRn

 

Required

Available

Ratio

Control

271.371 kN

1648.959 kN

0.165

Bolt Bearing on End Plate

Bearing strength limit states of the connection plate that are “shear tear out” and “ovalization of bolt hole” for both end and inner bolts are checked according to AISC 360-16.

dh

36+3=39 mm

 

Lc,edge

 

Rn

AISC 358-16 6.8-12

Rn-edge

 

Lc,spacing

 

Rn-spacing

 

Rn

 

ΦRn

 

Required

Available

Ratio

Control

271.371 kN

3307.716 kN

0.082

Bolt Bearing on Column Flange

Bearing strength limit states of the connection plate that are “shear tear out” and “ovalization of bolt hole” for both end and inner bolts are checked according to AISC 360-16.

db

36 mm

 

Rn

AISC 358-16 6.8-12

Rn-edge

 

Lc,spacing

 

Rn-spacing

 

Rn

 

ΦRn

 

Required

Available

Ratio

Control

271.371 kN

3953.318 kN

0.069

Beam Web to End Plate Weld Size

The required end weld sizefor four bolts stiffened end plate connection is checked according to AISC 358-16 §6.7

Fyp

275000 kN/m2

AISC 358-16

(6.7.6) 3

tbw

9 mm

 

F e

490000 kN/m2

 

w

 

Required

Available

Ratio

Control

4.763 mm

7.072 mm

0.673

Column Flange Thickness

The required column flange thickness, tcf, for four bolts unstiffened end plate connection is checked according to AISC 358-16 §6.8

Muc

821.813 kNm

AISC 358-16 (6.8-13)

Fyp

275000 kN/m2

 

s

 

c

 

Yc

 

Yc

 

tcf

Required

Available

Ratio

Control

25.618 mm

31 mm

0.826

Column Panel Zone Shear

Yielding of the column panel zonefor four bolts unstiffened end plate connection is checked according to AISC 360-16 §J.10

Pr

355.597 kN

AISC 360-16 J10-9

Py

 

Fy

275000 kN/m2

 

Ag

28634.759 mm2

 

dc

650 mm

 

tw

16 mm

 

Rn

 

ΦRn

 

Required

Available

Ratio

Control

1673.526 kN

1716 kN

0.975

Panel Zone Thickness

The required panel zone thickness for four bolts unstiffened end plate connection is checked according to AISC 358-16.

tmin≥u/180

TBDY 2018 9.3.4.2b

t min = tw

16 mm

 

tw

16 mm

 

u

2016 mm

 

Required

Available

Ratio

Control

11.2 mm

16 mm

0.700

...