Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • The clear span-to-depth ratio of the beam is limited:

    • For SMF systems, seven or greater.

    • For IMF systems, five or greater.

  • The protected zone is determined:

    • For unstiffened extended end-plate connections: the portion of the beam between the face of the column and a distance equal to the depth of the beam or three times the width of the beam flange from the face of the column, whichever is less.

    • For stiffened extended end-plate connections: the portion of the beam between the face of the column and a distance equal to the location of the end of the stiffener plus one-half the depth of the beam or three times the width of the beam flange, whichever is less.

  • The end plate should be connected to the flange of the column.

  • The rolled-shape column depth is limited to W36 (W92036 in. (920 mm.) maximum. The depth of built-up wide-flange columns does not exceed that for rolled shapes.

...