Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The nominal and design yield strength of the web plate is checked according to AISC 360-16

Ag

Image Removed

Mathinline
body--uriencoded--$$ \normalsize A_%7Bg%7D = L_p \times t_ p = (450 - 2 \times 15 - 2 \times 30 ) \times 9 =3240 \; \; \mathrm%7Bmm%5e2%7D $$

 

Fy

275 N/mm2

 

Rn

Image Removed

Mathinline
body--uriencoded--$$ \normalsize R_n = 0.6F_%7By%7DA_%7Bg%7D =0.6 \times 275 \times 10%5e%7B-3%7D \times 3240 = 534.6 $$

AISC 360-16 J4-3

ΦRn

Image Removed

Mathinline
body$$ \normalsize \varphi R_n = 1 \times 534.6 = 534.6 $$

 

Required

Available

Ratio

Control

265.569 kN

534.6 kN

0.497

...

Fe

490000 kN/m2

AISC 360-16 J2-3

w

12.73 mm

 

l

380 mm

 

Rreq

Image Removed

Mathinline
body--uriencoded--$$ \normalsize R_%7Breq%7D = h_p t_ p ( 0.6 R_y F_%7Byp%7D ) $$
Mathinline
body--uriencoded--$$ \normalsize R_%7Breq%7D = 380 \times 10 \times (0.6 \times 1.3 \times 275 \times 10%5e%7B-3%7D ) =815.1 $$

 

hp

380 mm

 

tp

10 mm

 

Ry

1.30

 

Fyp

275 N/mm2

 

Rn

Image Removed

Mathinline
body--uriencoded--$$ \normalsize R_%7Bn%7D = 0.6 F_E 0.707 wl $$
Mathinline
body--uriencoded--$$ \normalsize R_%7Bn%7D = 0.6 \times 490 \times 10%5e%7B-3%7D \times 0.707 \times 12.73 \times 380 =1005.49 $$

 

ΦRn

Image Removed

Mathinline
body$$ \normalsize \varphi R_n = 0.90 \times 1005.49 = 904.94 $$

 

Required

Available

Ratio

Control

815.1 kN

904.94 kN

0.901

...

Pr

429.124 kN

AISC 360-16 J10-9

Py

Image Removed

Mathinline
body--uriencoded--$$ \normalsize P_y = F_%7By%7DA_%7Bg%7D = 275 \times 10%5e%7B-3%7D \times 28634.759 = 7874.559 $$

 

F y

275000 kN/m2

 

A g

28634.759 mm2

 

dc

650 mm

 

tw

16 mm

 

Rn

Image Removed

Mathinline
body--uriencoded--$$ \normalsize R_n = 0.6 F_%7By%7D d_c t_w =0.6 \times 275 \times 10%5e%7B-3%7D \times 650 \times 16 = 1716 $$

 

ΦRn

Image Removed

Mathinline
body$$ \normalsize \varphi R_n = 1 \times 1716 = 1716 $$

 

Required

Available

Ratio

Control

1497.795 kN

1716 kN

0.873

...

The required panel zone thicknessfor welded web connection is checked according to AISC 358-16.

tmin ≥u / 180

Image Removed

Mathinline
body--uriencoded--$$ \normalsize t_%7Bmin%7D = 16 \geq 2016 / 180 = 11.2 \; \; \mathrm%7Bmm%7D $$

tmin = tw

16 mm

tw

16 mm

u

2016 mm

...