Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#E3FCEF

Download ideCAD for International Building Code

Get Started for FREE Structural Engineering Software

IBC Options Tab

...

Specifications

Seismic Code Parameters Wizard

It displays the analysis settings wizard where the parameters specific to IBC are determined step by step. On the wizard screen, you can assign the site class, risk category, horizontal and vertical response spectrum, seismic design category, stories, stories, structural system, diaphragm, structural system type ​​to be used.

Structural system type

The type of structural system for X and Y direction is selected in accordance with the design of the building.

Response modification coefficient

It is the response modification coefficient value. This row is automatically refreshed when the structural system type is chosen.

Overstrength factor

It is the strength excess coefficient value. This row is automatically refreshed when the structural system type is chosen.

Deflection amplification factor

It is the deflection amplification factor value. This row is automatically refreshed when the structural system type is chosen.

Redundancy factor

It is the redundancy factor value. This row is automatically refreshed when the structural system type is chosen.

ELF Ct parameter

It is the ELF Ct parameter. This row is automatically refreshed when the structural system type is chosen.

ELF x parameter

It is the ELF x parameter. This row is automatically refreshed when the structural system type is chosen.

Accidental eccentricity ratio

The eccentricity ratio to be used during the analysis is given as a percentage.

Use custom vertical seismic load factor

If checked, the custom vertical seismic load factor which entered in "factor to use (instead of 0.2 SDS)" line is used.

Structural system

If the building block consists of only concrete elements, Concrete; if it consists of only steel elements, Steel; Steel + Concrete option is selected if it consists of concrete and steel elements.

Building Risk Category

Building risk category value is selected from the list according to the purpose of use of the building.

Story drift check

Allowable story drift value is entered.

...