Note

In earthquake design class (DTS) 3 or 4 unidirectional geared reinforced concrete carrier structural systems, the condition Mdev / Mo> = 0.75 must be met.

...

According to article 4.3.4.6 of TBDY , ductility level should be provided in mixed carrier structural systems (4.3) .

                                                              ∑ M DEV ≥ 0.75 M o                                                       (4.3)

 

Possible solutions:

  • A curtain Shearwall / curtain shearwall group can be added to the carrier structural system until the 4.3 condition is met.

  • If the building height class is BYS> = 7, a solution can be made by selecting A31 .

...

M o = Total tipping moment at the base from earthquake loads for the entire building

...