A sample of a single plate design report according to AISC 360-16 is given below.

...

Tip
  • Single plate connection limit states and geometry checks are done automatically according to AISC 360-16.

Tip
  • The block shear limit state is checked automatically according to AISC 360-16.

Tip
  • Limit states of single plate flexural yield, plate flexural bucking, and weld strength are checked automatically.

...