changes.mady.by.user nurgül Kaya
Saved on Sept 08, 2020
changes.mady.by.user oğuzcan hadim
Saved on Feb 06, 2024
...
A sample of a single plate design report according to AISC 360-16 is given below.
Single plate connection limit states and geometry checks are done automatically according to AISC 360-16.
The block shear limit state is checked automatically according to AISC 360-16.
Limit states of single plate flexural yield, plate flexural bucking, and weld strength are checked automatically.
Next Topic
Single Angle Connection Design per AISC 360-16
Related Topics
Single Plate Connection Design per AISC 360-16
Double Angle Connection Design per AISC 360-16
T-Plate Connection Design per AISC 360-16
End Plate Shear Connection Design per AISC 360-16
Unstiffened Seated Connection Design per AISC 360-16