Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Analysis settings that vary depending on the MOPC R-001 are explained in detail.

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#E3FCEF

Download ideCAD for Seismic Code Design with MOPC R-001

Get Started for FREE Structural Engineering Software

MOPC R-001 Options Tab

...

Specifications

Structural system type

Image Modified

The type of structural system for X and Y direction is selected in accordance with the design of the building.

Response modification coefficient

Image Modified

It is the response modification coefficient value. This row is automatically refreshed when the structural system type is chosen.

Deflection amplification factor

Image Modified

It is the deflection amplification factor value. This row is automatically refreshed when the structural system type is chosen.

Redundancy factor

Image Modified

It is the redundancy factor value. This row is automatically refreshed when the structural system type is chosen.

ELF Ct parameter

Image Modified

It is the ELF Ct parameter. This row is automatically refreshed when the structural system type is chosen.

ELF x parameter

Image Modified

It is the ELF x parameter. This row is automatically refreshed when the structural system type is chosen.

Accidental eccentricity ratio

Image Modified

The eccentricity ratio to be used during the analysis is given as a percentage.

Use custom vertical seismic load factor

Image Modified

If checked, the custom vertical seismic load factor which entered in "factor to use (instead of 0.2 SDS)" line is used.

Structural system

Image Modified

If the building block consists of only concrete elements, Concrete; if it consists of only steel elements, Steel; Steel + Concrete option is selected if it consists of concrete and steel elements.

Building Risk Category

Image Modified

Building risk category value is selected from the list according to the purpose of use of the building.

Story drift check

Image Modified

Allowable story drift value is entered.

Response Spectrum Tab

...

Specifications

Spectrum curve

Image Modified

The spectrum curve resulting from the settings is shown.

Function name

Image Modified

The name of the spectrum function.

Spectrum multiplier

Image Modified

Factor of spectrum function.

0.2 sec spectral acceleration (Ss)

Image Modified

0.2 sec spectral acceleration of spectrum function.

1 sec spectral acceleration (S1)

Image Modified

1 sec spectral acceleration of spectrum function.

Site class

Image Modified

Site class is selected.

Short-period site coefficient (Fa)

Image Modified

Short-period site coefficientof spectrum function.

Long-period site coefficient (Fv)

Image Modified

Long-period site coefficientof spectrum function.

T0/Ts

Image Modified

Spectrum Characteristic Periods.

...

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#E3FCEF

Download ideCAD for MOPC R-001

Get Started for FREE Structural Engineering Software