Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

In the sample relative floor displacement report, relative floor displacement controls are not provided at the 2nd and 1st floors in the Y direction + 5% (Modal E3) loading.

  1. katta → λ * δ

i(max) / hi = 0.009858> 0.008

  1. katta → λ * δ

i(max) / hi = 0.01010> 0.008

...

  • In thin and long structures, if you make the carrier system strong in the short direction, it will help to ensure the relative floor displacement

  • Flaky frames have a negative effect. Making the frame continuous by adding beams at the axles where the frame is discontinuous can help to provide relative story offsets.

  • If the superstructure-foundation interactive solution is made, the floor horizontal coefficient is effective. Check if it has been entered correctly. In cases where the superstructure-foundation interactive solution is made, increasing the foundation thickness can help provide relative story offsets.

  • Increasing the beam dimensions can contribute to the relative story offset.

  • Provided that it is built on site , TBDY may consider applying Article 4.9.1.3b . There is an option in the analysis settings. Application of TBDY Article 4.9.1.3b increases the relative floor offset upper limit by 2 times.

...