How does ideCAD define T-Beam effective flange width according to ACI 318-19?
...
Tip |
---|
|
...
Notation
bf = effective flange width, in.
bw = web width or diameter of circular section, in.
h = overall thickness, height, or depth of the member, in.
ln = length of clear span measured face-to-face of supports, in.
sw = clear distance between adjacent webs, in.
...
Panel | |||||
---|---|---|---|---|---|
|
...
| |
Download ideCAD for ACI 318-19 |
In non prestressed T-Beam monolithic concrete construction, the effective flange width bf equals the beam width bw plus an effective overhanging flange width in accordance with ACI Table 6.3.2.1.
Flange location | T-beam overhanging flange width | ||||||
---|---|---|---|---|---|---|---|
Eacg side of web |
| ||||||
One side of web |
|
h is the slab thickness and sw is the clear distance to the adjacent web.
...
According to ACI 6.3.2.2, isolated nonprestressed T-beams, as used to provide additional compression area, should have a flange thickness greater than or equal to 0.5bw and an effective flange width less than or equal to 4bw.
...