Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Table of Contents

...

How does ideCAD design End Plate Moment Connections

...

It consists of 3 different types.

...

The factors determining the behavior of the combination; beam cross-section reaching to yield under bending effect, end plate reaching to yield under bending effect, yielding of column panel area, rupture of bolts under tensile effect, rupture bolts under shear effect.

...

according to AISC 358-16 & AISC 360-16?

...

Tip
  • Limit states of end plate moment connections are calculated automatically according to AISC 358-16 and AISC 360-16.

...

Symbols

bbf = width of beam flange, in. (mm)
bp = width of end-plate, in. (mm)
d = depth of connecting beam, in. (mm)
g = horizontal distance between bolts, in. (mm)
pb = vertical distance between the inner and outer row of bolts in an eight-bolt stiffened connection, in. (mm)
pfi = vertical distance from the inside of a beam tension flange to the nearest inside bolt row, in. (mm)
pfo = vertical distance from the outside of a beam tension flange to the nearest outside bolt row, in. (mm)
tbf = thickness of beam flange, in. (mm)
tp = thickness of end-plate, in. (mm)

...

Bolted Stiffened and Unstiffened End Plate Connections

End-plate connections consist of welding the beam to an end-plate and bolting the end-plate to a column flange.

If there is no axial load on the connection, total tensile and compressive forces are equal and opposite in both flanges, so that total force creates a force pair. It is accepted that the center of rotation is in the center of the compression flange.

Extended end-plate moment connections are prequalified in special moment frame (SMF) and intermediate moment frame (IMF) systems. Configurations of extended end-plate moment connections are given below.

  • Four Bolts Unstiffened End Plate Connection (a)

  • Four Bolts Stiffened End Plate Connection (b)

  • Eight Bolts Stiffened End Plate Connection (c)

...

The limit states of end-plate moment connections are listed below.

  • Flexural yielding of the beam section

  • Flexural yielding of the end plates

  • Yielding of the column panel zone

  • Tension rupture of the end-plate bolts

  • Shear rupture of the end-plate bolts

  • Rupture of various welded joints.

The limit state checks listed above are applied automatically, and detailed explanations, references, and parameters used in the account are given in the connection report.

...

There are

...

prequalification limits for moment connections that have been satisfactorily tested. All end-plate moment connection configurations should satisfy these beam and column limitations. Beam and column limitations are given in AISC 358-16 6.3. ideCAD

...

Structural automatically checks

...

Beam and column limitations.

Parametric Limitations on Prequalification

Four-Bolt Unstiffened

Four-Bolt Stiffened

Eight-Bolt Stiffened

Parameter

Maximum
in. (mm)

Minimum
in. (mm)

Maximum
in. (mm)

Minimum
in. (mm)

Maximum
in. (mm)

Minimum
in. (mm)

tbf

3/4 (19)

3/8 (10)

3/4 (19)

3/8 (10)

1 (25)

9/16 (14)

bbf

91/4 (235)

6 (152)

9 (229)

6 (152)

121/4 (311)

71/2 (190)

d

55 (1400)

133/4 (349)

24 (610)

133/4 (349)

36 (914)

18 (547)

tp

21/4 (57)

1/2 (13)

11/2 (38)

1/2 (13)

21/2 (64)

3/4 (19)

bp

103/4 (273)

7 (178)

103/4 (273)

7 (178)

15 (381)

9 (229)

g

6 (152)

4 (102)

6 (152)

31/4 (83)

6 (152)

5 (127)

pfi , pfo

41/4 (114)

11/2 (38)

51/2 (140)

13/4 (44)

2 (51)

15/8 (41)

pb

-

-

-

-

33/4 (95)

31/2 (89)

Plastic hinges cause inelastic bending deformations in the joining beam and column

...

panel zones. Therefore, panel zones should conform to the requirements of the AISC Seismic Provisions. In addition, Column-beam moment ratios should conform to the requirements of the AISC Seismic Provisions.

Also, it should be checked that:

  • The clear span-to-depth ratio of the beam is limited:

    • For SMF systems, seven or greater.

    • For IMF systems, five or greater.

  • The protected zone is determined:

    • For unstiffened extended end-plate connections: the portion of the beam between the face of the column and a distance equal to the depth of the beam or three times the width of the beam flange from the face of the column, whichever is less.

    • For stiffened extended end-plate connections: the portion of the beam between the face of the column and a distance equal to the location of the end of the stiffener plus one-half the depth of the beam or three times the width of the beam flange, whichever is less.

  • The end plate should be connected to the flange of the column.

  • The rolled-shape column depth is limited to 36 in. (920 mm.) maximum. The depth of built-up wide-flange columns does not exceed that for rolled shapes.

End Plate Connections Design Steps

  • The strength of the end plate moment connection is determined by the assumption that the rupture limit state controls the tensile force of the bolts in one flange is controlled by rupture limit state under compressive force in the other.

  • If there is no axial load on the joint, the total tensile and compressive forces are equal and opposite in both flanges , so that the total force creates a force pair.

  • The row of bolts farthest from compression flange is considered as the region subject to the greatest tensile force, and while the inverse triangular force distribution is considered for ease of calculation, and a ductile joint is calculated on a parabolic distribution according to the plastic force distribution assumption.

    Image Removed

    Flexural strength of flexural strength of the end plate and column flange is determined by yield line analysis. The yield line method can be mechanism is calculated by the energy or virtual work method.

  • Strong A strong column, strong joint, and weak beam are used to calculate the forces on the bolt and to find the required bolt strength. According to this assumption, while the column, panel region zones, and beam have inelastic behaviordeformation, the joint connection and column show have elastic behavior. For this reason, it is necessary to design a suitable thickness for the thick plate for end plate. In thick plate behavior, the force in the bolts is the static moment at the center of comprensive flange.

    • The equations used are as follows:

...

Boundary Situations to Check

...

Effective Force

...

Connection Element

...

Reference

...

Do not Pull

...

Bolt (Pull)

...

a

...

Do not Pull

...

Plate (Bending)

...

b

...

Do not Pull

...

Column head (Tilt)

...

c

...

Do not Pull

...

Beam body (Tensile)

...

d

...

Do not Pull

...

Column body (Tensile)

...

is

...

Do not Pull

...

Title - Plate welding

...

f

...

Do not Pull

...

Body-Plate welding

...

g

...

Horizontal Cut

...

Column body (Cutting)

...

h

...

Pressure

...

Beam head (Pressure)

...

j

...

Pressure

...

Beam head welding

...

to

...

Pressure

...

Column body

...

l

...

Vertical Cutting

...

Body - Plate welding

...

m

...

Vertical Cutting

...

Bolt (Cutting)

...

n

...

Vertical Cutting

...

Bolt crush

...

p

...

Mathinline
body--uriencoded--$$ \normalsize M_%7Bnp%7D =n P_%7Bt%7D \displaystyle \sum_%7Bi=1%7D%5e%7BN%7D h_i $$

Mathinline
body$$ \normalsize P_t=F_tA_b $$

...

Child pages (Children Display)

...