How ideCAD defines ductile internal forces according to ASCE 7-16?

...

Tip
  • The overstrength factor Ωo= 1 is taken automatically in the

calculation of the reduced internal forces
  • design internal force calculation.

...

Symbols

Ωo = Overstrength factor

The overstrength factor is not used in calculating the reduced internal forces corresponding to the special, intermediate or ordinary ductile behavior of the structural system elements.

...

Internal forces that oppose ductile behavior are flexural moment, tensile force, and similar internal forces. Ductility is the name given to the ability to make large displacements without losing strength. Overstrength The overstrength factor, Ωo, is not used in reduced internal forces such as flexural moment and axial force, which have ductile behavior.

...