With the Single Footing Settings command, settings such as single footing size, height, elevation, drawing, material selection, structural material can be accessed.

Location of the Single Footing Settings Dialog

...

You can access it under the ribbon menu Concrete tab Foundation title.

...

General Settings Tab

...

Specifications

Footing ID

Image Modified

It is the name of the single footing. The letter T is placed in front of the number entered here and the name of the single footing is created and written on the footing in the plan. The number is increased according to the order in which the footings are drawn (such as T1, T2, T3 ....). The single base names can be changed later using the Name Object command. The name index does not have to be T. Different indices can be used for renaming.

Outer frame color

Image Modified

The color of the individual base outline (s). The color palette is scrolled by clicking and holding down the left mouse button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. Pen thickness is not noticeable on the screen. The drawing is valid when drawn on paper.

Inner frame color

Image Modified

It is the color of the frame around the single footing. The color palette is scrolled by clicking and holding down the left mouse button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. Pen thickness is not noticeable on the screen. The drawing is valid when drawn on paper.

Connection line color

Image Modified

It is the color of the lines connecting the inner frame and outer frame corner points. The color palette is scrolled by clicking and holding down the left mouse button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. Pen thickness is not noticeable on the screen. The drawing is valid when drawn on paper. If the connection lines are trapezoidal (if the height at the edge is different from the height at the column level), it is drawn. In cases where the two heights are equal, the connection line is not drawn because the basic will be rectangular.

Line type

Image Modified

The line type of the line forming the single footing is selected in the plan. Clicking the down arrow buttons to the right of the boxes opens the list of line types. From this list, the desired line type is selected by clicking with the left mouse button.

Frame distance

Image Modified

A frame surrounding the column can be drawn on a single footing where the column rests on a single footing. The distance of the frame from the column face is entered in this box. If the frame is required to be drawn, check the option "There is an inner frame". If this option is not checked, the frame will not be drawn.

Dim X

Image Modified

It is the dimension of the single footing parallel to the X dimension of the column resting on it. Column X dimension is the column dimension in the column axis direction. The column axis is the arrow drawn from the column node. If the "Draw column axis" option is selected from Settings/General Settings/Preferences in the classic menu, Settings/Settings/Preferences in the ribbon menu, it appears on the column on the screen.

Dim Y

Image Modified

It is the dimension of the single footing parallel to the Y dimension of the column resting on it. The column Y dimension is the dimension perpendicular to the column axis.

Delta X

Image Modified

It is the alignment of the single footing in the column local X-axis direction. If the delta X is zero, the left edge of the single footing coincides with the left edge of the column. If positive, the left edge of the single footing shifts to the left by the value entered from the left edge of the column. If negative, the left edge of the single footing shifts to the right by the value entered from the column left edge. The directions should be considered according to the local axis of the column.

Delta Y

Image Modified

It is the alignment of the single footing in the column local Y axis direction. If the delta Y is zero, the upper edge of the single footing coincides with the upper edge of the column. If it is positive, the upper edge of the single footing will slide up by the value entered from the upper edge of the column. If negative, the upper edge of the single footing shifts down by the value entered from the upper edge of the column. The directions should be considered according to the local axis of the column.

Height at edge

Image Modified

It is the vertical (in z direction) height of the single footing at the edge. If single footings with trapezoidal cross-section are to be made, the footing height at the edge should be smaller than the footing height at the column level. For single footings with rectangular cross section, the heights at the side and at the column level should be equal.

Height at column edge

Image Modified

It is the vertical (in z direction) height of the single footing at the level of the column face. If single footings with trapezoidal cross-section are to be made, the footing height at the column level should be greater than the footing height at the edge. For single footings with rectangular cross section, the heights at the side and at the column level should be equal.

Elevation

Image Modified

The single footing is higher than the story floor. When the elevation is zero, the upper surface of the single footing coincides with the floor base. If a negative value is entered in the level section, the base floor slides down from the base. Positive values ​​shift the footing up from the floor base. If the individual footing level is changed, the column level on the footing must also be changed accordingly. If not replaced, the column will not sit on the footing.

Advanced Tab

...

Specifications

ID text

Image Modified

The height of the single footing name text is entered. The color box is slid over the color palette that is opened by clicking with the left mouse button and holding down the button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. If the button just below is clicked, the Font Settings dialog opens. From this dialog, the Column Header Name Text, font is set. Articles are written horizontally.

Dimension text

Image Modified

The height of the single footing dimension text is entered. The color box is slid over the color palette that is opened by clicking with the left mouse button and holding down the button. The button is released when the desired color is reached. The color box turns into the selected color. If clicked together with the Shift key, the pen thickness of the relevant color can be adjusted. If the button just below is clicked, the Font Settings dialog opens. From this dialog, the Column Header Size Text, font is set. Articles are written horizontally.

Text X/Text Y

Image Modified

X and Y coordinates are entered according to the upper left corner of the column heading of the single footing ID text. Text If the X value is positive, the name text will move to the left, if it is negative, it will move to the right. Text scrolls up if the Y value is positive, and down if it is negative.

Dim X/Dim Y

Image Modified

X and Y coordinates are entered according to the upper right corner of the column heading of the single footing dimension text. If the dimension X value is positive, the dimension text shifts to the left, if it is negative, it shifts to the right. If the dimension Y value is positive, the dimension text will scroll up, and if it is negative, it will scroll down.

Material

Image Modified

The material to be covered on the footings in the solid model is selected. The base is covered with the selected material and displayed as such in the solid model. Click on the down arrow button with the left mouse button. The appropriate material is selected from the opened material list. If there is no defined item, the list is blank. Adding material is done from the dialog that opens by clicking Settings/Materials line in the classic menu and Settings/Settings/Materials in the ribbon menu.

Texture world length

Image Modified

Text length is entered. For example; If 1 meter is entered, the selected material texture is taken as 1 meter and covered on the selected object. Considering that the texture is in the form of a square, the object surfaces are covered with 1x1 textures arranged side by side.

Components Tab

...

Add Building Components : Assigns the building materials defined for detailed building components metrics to the object.

...

Following are the lines that appear in the Proportion list according to the single footing object and material size.

Single Footing

Measure

Listed

Explanation

Constant

Independent

The fixed measure used will be used exactly as the amount.

Length

Independent

It means that the length measure found while defining the material will be used exactly as the length value.

Perimeter

It means that the length of the material will be found by multiplying the perimeter of the single footing with the length measure found while defining the material.

Height

It means that the length of the material will be found by multiplying the length measurement found when defining the material and the height of the single footing.

Area

Independent

It means that the area measure found while defining the material will be used exactly as the amount.

Volume

Independent

The volume measurement found when defining the material will be used exactly as the volume value.

Volume

It means that the volume measurement found when defining the material will be used by multiplying the floor volume.

Count

Independent

The number measure found while defining the material will be used exactly as the material number.

Count

The count measure found while defining the material will be used exactly as the material count.

...