Specifications |
Case name Enter a description. |
Type of modes calculation "Eigen vectors" or "Ritz vectors" can be selected from the calculation methods to be used in modal analysis. |
Target mode count Give the number of modes to consider in modal analysis. The program will automatically perform the mode adequacy check according to the TDY. In case of insufficient, the entered number should be increased. |
Targeted dynamic participation ratio The rate at which the total building mass will be taken into account as a minimum is determined. Its greatest value is 1. If the mass participation rate remains below the specified value, it is shown as a warning in the reports. |
Convergence tolerance Enter the convergence value to be used in the modal analysis. The default value is fine. |
Iteration count Give the number of iterations that will be accepted in the modal analysis. The default value is fine. |
Dynamic degrees of freedom Uninterested degrees of freedom can be revoked at will. |
...
Next Topic