As'= area of the compression reinforcement, in2
b = width of compression face of member, in.
d= distance from extreme compression fiber to centroid of logitudinal longitudinal tension reinforcement, in.
ρ' = ratio of As' to bd
ξ = time-dependent favtor factor for sustained load
λΔ = multiplier used for additional deflection due to long-term effects

...

Time-dependent factor ξ is 2.0 in accordance with ACI Table 24.2.4.1.3

Sustained load duration, months

Time-dependent factor, ξ

3

1.0

6

1.2

12

1.4

60 or more

2.0

...