Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Steel connection design using the Design, Calculation and Construction Principles of Steel Structures (ÇYTHYEDY) (GKT and CYTHYE 2016 (GKT & YDKT), AISC 360-16 (ASD and & LRFD) regulationsor EN 1993-1-1 codes; Strength checks, bolt checks, welding checks, and plate checks are carried out in accordance with the connection type and regulations.

  • Tensile strength control in check bolts

  • Shear strength control in check bolts

  • Bolt hole crush controlcheck

  • Bolt diameter controlcheck

  • Block break controlshear check

  • Plate tensile strength controlcheck

  • Plate yield controlcheck

There are deficiencies in strength checks for the relevant section in the connection design report. Necessary precautions can be taken for plates and bolts with these deficiencies.

...

Possible Solutions:

  • The relevant bolt diameter can be reduced.

  • The number of bolts can be increased.

  • The connection plate thickness can be increased.

  • The corresponding weld thickness can be increased.

  • The connection type can be changed.

  • The cross-sections of the column and beam elements where the connection is defined can be changed to create the connection geometry.

...