The Complete Message:

Carrier system type A23 (in X / Y direction) is selected. Curtains should be used in A23 carrier systems.


A23 bearing system is defined in the earthquake regulations as buildings where the moment-transferring ductility level of the earthquake impacts are met by single-direction geared reinforced concrete frames with or without filling (hollow blocks) and reinforced concrete walls with high ductility level bond beams (hollow).

However, the curtain is not defined in the project.

Possible solutions:

  • Curtains should be added in the direction requested in accordance with the A23 carrier system in the project .

  • If curtain will not be used in the building, A31 must be selected in the Analysis Settings / TBDY 2018 Earthquake Code Wizard. Bearing systems consisting of filled (filler) or unfilled single-direction geared reinforced concrete frames will be classified as structural systems with limited ductility level and will only be used in buildings with DTS = 3 and DTS = 4. (TBDY 4.3.4.3)