Location of Curtain Wall Settings Command
You can access it under the Ribbon menu, Facade tab, Exterior Facade title.
General Tab
Specifications |
|
---|---|
Curtain wall name A name is given for the curtain wall object. | |
Color Select the color of the curtain wall object from the color palette that opens when clicked. | |
Line type Select the line type of the lines of the curtain wall object that appear in the plan from the line type list that opens when clicked. | |
Jeans Level the curtain wall object with respect to the floor base. | |
Height Give the height of the curtain wall object. | |
Reverse It takes the symmetry of the object with respect to its axis. | |
Residential It determines the location of the boundary frame. Select one of the appropriate in-grid, in-grid, out-of-grid options according to the layout you want to apply. | |
Limits Regulates whether the frame that passes through the outermost part of the curtain wall is created to the left, right, above or below the object. You can create the frame by checking the option in the relevant direction. | |
Placement direction It determines how the curtain wall elements will be placed and balanced horizontally. Mark the appropriate option from the beginning, middle or end. | |
Detailed It shows all the lines of the element in the plan drawing. | |
Drawing by quota It determines the plan drawing of the curtain wall element. For example, if the value is 1.5 meters on a facade with a height of 15 meters, the facade is cut from a height of 1.5 meters and its plan is drawn to look down. | |
Show outside direction In the plan drawing on the curtain wall, an arrow is drawn to show where the outer side is. This option determines whether that arrow is drawn in the plan. |
Unit Scheme Tab
Specifications |
|
---|---|
Vertical recording The number of parts to be formed in the vertical direction of the module forming the curtain wall element and their intervals are set in this table. While a new record is opened with the Add button at the bottom, an existing record is deleted with the Delete button. In the vertical recording intervals column of the table, give the distance between the two records in turn. The created partition can be followed in the preview box on the right. | |
Horizontal recording The number of pieces to be formed in the horizontal direction of the module forming the curtain wall element and their intervals are set in this table. While a new record is opened with the Add button at the bottom, an existing record is deleted with the Delete button. In the column of horizontal recording intervals in the table, give the distance between the two records in turn. The created partition can be followed in the preview box on the right. | |
Total The total length of the module constituting the curtain wall element is given in this line. | |
Add Adds a record to the table. | |
Delete Deletes a record from the table. | |
Clean Deletes all the records that make up the module and prepares a new worksheet. | |
Model preview It is the front view of the curtain wall module prepared by defining vertical and horizontal registration. In the model, T1, T2 designations are horizontal, M1 and M2 etc. nomenclature refers to vertical record lengths. Each eye forms the entire model, and the model is brought side by side to form the curtain wall element. When the eye (panel) forming the model is clicked with the left mouse button, it undergoes a color change specified as general, type1, type2, and type3. These are the item names defined in the Panel tab. By default, the general type of material is defined and one of these materials can be assigned to each compartment also in the border, vertical and horizontal tabs. |
Boundary Tab
Specifications |
---|
Types Four types are defined as general, type1, type2, and type3, and each type is associated with a material. Assign the materials you want to the type you want from the material list on the side by selecting the types from the table. |
Materiel Clicking the arrow opens the list of available items. Select the appropriate material from the list. |
Actual tissue length Tissue length is entered. For example; If 1 is entered, the width of the selected material texture is taken as 1 unit and overlaid on the selected object. Considering that the texture is in the form of a square, the object surfaces are covered with 1x1 textures arranged side by side. |
Priority The border determines the priority of intersection in horizontal and vertical records. The smaller the value, the higher the priority and the intersection of that element is made ahead of the others. |
General When checked, the profiles (registration and caps) that limit the curtain wall element appear. |
Stored record When marked, the profiles (registers and covers) that limit the curtain wall element are not visible (stored) on the façade of the building, but visible internally (from the interior of the building). |
No When marked, the profiles that limit the curtain wall element are completely closed. (It does not appear in any direction.) |
Offsets The geometric properties of the profile forming the curtain wall element boundary are given according to the parameters shown in the diagram. These parameters can change according to the general, stored record and non-existent type. |
Mullion Tab
Specifications |
---|
Types Four types are defined as general, type1, type2, and type3, and each type is associated with a material. Assign the materials you want to the type you want from the material list on the side by selecting the types from the table. |
Materiel Clicking the arrow opens the list of available items. Select the appropriate material from the list. |
Actual tissue length Tissue length is entered. For example; If 1 is entered, the width of the selected material texture is taken as 1 unit and overlaid on the selected object. Considering that the texture is in the form of a square, the object surfaces are covered with 1x1 textures arranged side by side. |
Priority The border determines the priority of intersection in horizontal and vertical records. The smaller the value, the higher the priority and the intersection of that element is made ahead of the others. |
General When checked, the curtain wall element vertical registration profiles (registration and hatches) appear. |
Stored record When marked, the curtain wall element vertical registration profiles (registers and covers) are not visible (stored) on the façade of the building, but visible internally (from the interior of the building). |
No When marked, the curtain wall element vertical registration profiles are completely closed. (It does not appear in any direction.) |
Offsets The geometric features of the profile forming the vertical registration of the curtain wall element are given according to the parameters shown in the diagram. These parameters can change according to the general, stored record and non-existent type. |
Transom Tab
Specifications |
---|
Types Four types are defined as general, type1, type2, and type3, and each type is associated with a material. Assign the materials you want to the type you want from the material list on the side by selecting the types from the table. |
Materiel Clicking the arrow opens the list of available items. Select the appropriate material from the list. |
Actual tissue length Tissue length is entered. For example; If 1 is entered, the width of the selected material texture is taken as 1 unit and overlaid on the selected object. Considering that the texture is in the form of a square, the object surfaces are covered with 1x1 textures arranged side by side. |
Priority The border determines the priority of intersection in horizontal and vertical records. The smaller the value, the higher the priority and the intersection of that element is made ahead of the others. |
General When checked, the curtain wall element horizontal registration profiles (registration and hatches) appear. |
Stored record When marked, the curtain wall element horizontal registration profiles (registration and covers) are not visible (stored) on the facade of the building, but visible from the inside (from the interior of the building). |
No When marked, the curtain wall element horizontal registration profiles are completely closed. (It does not appear in any direction.) |
Offsets The geometric features of the profile forming the horizontal record of the curtain wall element are given according to the parameters shown in the diagram. These parameters can change according to the general, stored record and non-existent type. |
Panel Tab
Specifications |
---|
Types Four types are defined as general, type1, type2, and type3, and each type is associated with a material. Assign the materials you want to the type you want from the material list on the side by selecting the types from the table. |
Materiel Clicking the arrow opens the list of available items. Select the appropriate material from the list. |
Actual tissue length Tissue length is entered. For example; If 1 is entered, the width of the selected material texture is taken as 1 unit and overlaid on the selected object. Considering that the texture is in the form of a square, the object surfaces are covered with 1x1 textures arranged side by side. |
Curtain thickness The thickness of the curtain wall curtain is given. |
Wackiness The deflection of the curtain wall is given. |