This connection is a column-beam connection.


Location of the 8 Bolts Stiffened End Plate Connection Command

You can access it under the Ribbon menu, Connection tab, Connection title.

Usage Steps

If Draw in Fast Mode is Active

  • From the Connectionmenu, click on the icon for 8 Bolts Stiffened End Plate Connection.

  • In 3D perspective view, move the mouse pointer closer to the element, close to the support

  • After this process, the virtual image of the connection will appear.

  • If the connection is suitable, create the connection by clicking the left mouse button.

  • The connection will occur with default settings.

If Draw in Fast Mode is Inactive

  • From the Connection menu, click on the icon for 8 Bolts Stiffened End Plate Connection.

  • Click the column then the beam before the 3D perspective view.

  • The 8 bolts stiffened end plate connection settings dialog will open.

  • The connection will occur when the wanted settings are made and the OK button is clicked.

Location of the 8 Bolts Stiffened End Plate Connection Settings Dialog

If the draw in fast mode is active, the connection settings will be opened automatically.

If the draw in fast mode is inactive, select the connection and click the right mouse button. Click the Properties line from the right click menu that opens.

8 Bolts Stiffened End Plate Connection Settings Dialog

Type and End Plates Tab

Specifications

End plate

The end plate is determined by entering the values. The values ​​to be entered are shown in the schematic drawing.

Schematic drawing

Connection and plate values ​​are shown on the schematic drawing.

Preview

There is a preview of the connection. The selection made and the entered values ​​can be followed simultaneously in the preview.

Brackets Tab

Specifications

Brackets

Brackets are determined by entering values. The values ​​to be entered are shown in the schematic drawing.

Schematic drawing

Connection and plate values ​​are shown on the schematic drawing.

Preview

There is a preview of the connection. The selection made and the entered values ​​can be followed simultaneously in the preview.

Bolts Tab

Specifications

Horizontal arrangement

The horizontal arrangement distance value of bolts is entered. The values ​​to be entered are shown in the schematic drawing.

Group 1

Distance values ​​of bolts to beam and other bolts are entered. The values ​​to be entered are shown in the schematic drawing.

Group 2

Distance values ​​of bolts to beam and other bolts are entered. The values ​​to be entered are shown in the schematic drawing.

Group 3

Distance values ​​of bolts to beam and other bolts are entered. The values ​​to be entered are shown in the schematic drawing.

Bolt properties

The Hole and Bolt Parameters dialog is opened by clicking on the bolt properties button. The bolt properties are set in this dialog.

Schematic drawing

Connection and bolt placement values ​​are shown on the schematic drawing.

Preview

There is a preview of the connection. The selection made and the entered values ​​can be followed simultaneously in the preview.

Retaining Boards Tab

The purpose of the continuity plates is to support the column heads in the column-beam connections and to ensure the continuity of the beam head. Continuity plates are used for reinforcement in order to bend the column head and prevent column stem flow / wrinkle. If a continuity plate will be made, the option is marked. The geometric properties of the sheet are adjusted according to the schematic picture given.

If there will be a continuity plate, tick the option and give the dimensions.

Extra Plates Tab

Body reinforcement board properties are set in this tab. If the column body thickness is insufficient, reinforcement plates are used to meet the shear effect of the panel area. If the body reinforcement plate will be made, the option is marked. The geometric properties of the sheet are adjusted according to the schematic picture given.

Chamfers Tab

For easy assembly of the plates in the field, the use of slope, slope type and geometric properties are determined in the connection settings dialog.

Welds Tab

The weld properties of the connections given in the schematic representation are set in the Welds tab. Give the size, type, angle values ​​and mark the option whether to weld under construction site conditions.

Welding geometry is determined automatically by the program. These properties can be changed to easily determine the connection properties. Geometry features are in accordance with industry standards and in the form specified in AISC.

Design Data Tab

In the design data, the plate material is defined. The condition that the main element in the weld joint has less strength than the weld strength is controlled.

If necessary, click the list and define "Create New…". To create the welding electrode, give the information "Name" and "Strength" in the dialog that opens after clicking "Create New".

  • No labels