Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »


Symbols

Ag : Gross cross-sectional area of member

Cw : Warping constant, in.6 (mm6)

E: Structural steel modulus of elasticity

Fcr : Critical stress

Fe : Elastic buckling stress determined according to Equation E3-4

Fy : Specified minimum yield stress of the type of steel being used

G: shear modulus of elasticity of steel = 11,200 ksi (77 200 MPa)

J: Torsional constant, in.4 (mm4)

K : Effective length factor

L: Laterally unbraced length of the member

Lcz : Effective length of member around the z-axis (= KL)

Ix , Iy : Moment of inertia about the principal axes, in.4 (mm4)

r: Radius of inertia


Torsional Buckling Limit State

  • Buckling occurs when the element rotates around its longitudinal axis. The limit state of torsional buckling is applicable to axially loaded columns with doubly symmetric open sections with very slender cross-sectional elements consisting of 4 corners placed back to back.

Design with AISC 360-16

  • The compressive strength of the elements is determined according to the axial force acting from the section center of gravity.

  • In the torsional buckling boundary case where buckling occurs by the rotation of the element around its longitudinal axis (+ shaped cross-section or open cross-section elements consisting of 4 corners placed back to back), the elastic buckling stress Fe is calculated for doubly symmetric members by equation E4.2.