ICONS


SDS = Short period design spectral acceleration coefficient [dimensionless]
SD1 = Design spectral acceleration coefficient for 1.0 second period [dimensionless]
SS = Short period map spectral acceleration coefficient [dimensionless]
S1 = Map spectral acceleration coefficient for 1.0 second period [ dimensionless]
T = Natural vibration period [s]
TA = Horizontal elastic design acceleration spectrum corner period [s]
TB   = Horizontal elastic design acceleration spectrum corner period [s]
TL = Transition period to the constant displacement region in the horizontal elastic design spectrum [s]
Sae(T) = Horizontal elastic design spectral acceleration [g]
SaR(T) = Reduced horizontal elastic design spectral acceleration [g]
R = Structural system response coefficient
Ra(T) = Earthquake load reduction coefficient
D  = Strength coefficient
I = Building importance factor


  • The excel file containing the following accounts can be accessed.


Reduced Design Spectrum of the Building

  • In TBDY 2018 4.2.1.2 , the horizontal elastic design spectrum is reduced with the earthquake load reduction coefficient Ra (T).

  • By using the Building Importance Factor I=1 and R=4.8, D=2.5 in the X and Y directions for the upper part of the building, a reduced horizontal elastic design spectrum in both directions was obtained for DD-2.

  • With the help of the following images excel Ra (T) and reduced design spectrum of the account is located account. The equations given above are used in this calculation.

  • The interval for T is taken as 0.005 s for precision calculation. Therefore, the entire spectrum cannot be shown in the image above. It is given below graphically.

  • To get the reduced design acceleration spectrum that the program calculates for the upper part, simply type 'exportspectrum' in the lower toolbar command line and press enter. Program spectrum txt. It saves the file as exp_spec.txt in the Computer: C: Program Files :ideCAD v10 folder. From here, you can take the txt file and compare the spectrum calculated by the program with the manual calculation in excel.

  • In the graph above, it is seen that the manually calculated reduced spectrum and the reduced spectrum calculated by ideCAD overlap and the calculation is correct.