  • Risk category and seismic importance factor defined by user.


SYMBOLS
Ie = Building Importance Factor


Risk Categorization and Importance Factor

Buildings or other structures is classified according to purpose of occupancy or type of building according to Table 1.5-1. An Seismic Importance Factor, Ie, should be choosen to each structure in accordance with Table 1.5-2.

Purpose of occupancy or type of building

Risk Category

Seismic Importance Factor, Ie

Buildings that represent low risk to human life in the event of failure

I

1.00

Buildings other than listed risk categories I, III, and IV

II

1.00

Buildings the failure of which could pose a substantial risk to human life

III

1.25

Buildings and other structures not included in Risk Category IV (including, but not limited to, facilities that manufacture, process, handle, store, use, or dispose of such substances as hazardous fuels, hazardous chemicals, hazardous waste, or explosives) containing toxic or explosive substances where the quantity of the material exceeds a threshold quantity established by the Authority Having Jurisdiction and is sufficient to pose a threat to the public if released

Buildings and other structures designated as essential facilities

Buildings and other structures, the failure of which could pose a substantial hazard to the community Buildings and other structures (including, but not limited to, facilities that manufacture, process, handle, store, use, or dispose of such substances as hazardous fuels, hazardous chemicals, or hazardous waste) containing sufficient quantities of highly toxic substances where the quantity of the material exceeds a threshold quantity established by the Authority Having Jurisdiction and is sufficient to pose a threat to the public if released

Buildings and other structures required to maintain the functionality of other Risk Category IV structures

IV

1.5