Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

This message is created by specifying the element name and floor on which it is located at the beginning of the report.

For example,

BE001 BASE STORY Section dimensions do not conform to TBDY Table 9.3.

The cross-section conditions of steel structural system beams with high ductility level and normal ductility level are checked in accordance with TBDY Table 9.3. The cap width/thickness and body height/thickness ratios of steel elements should not exceed the λ hd or λ md limit value given in Table 9.3.

For detailed information, you can review the title below.

TBDY 2018 Controls for Steel Carrier System Types

Possible Solutions:

  • The cross section of the steel element whose name and floor are given can be changed.

  • When choosing a steel beam cross-section, a cross-section selection can be made to reduce the header width/thickness or body height/thickness ratio.

  • This cross-section condition is not met in the majority of my HEA type profiles. For this reason, another type of profile can be chosen.

  • If the structure is suitable, the ductility level can be resolved to a limited extent.

TBDY Table 9.3 is given below.

image-20240120-105907.png

icons

λ hd : Cross-section condition limit value for elements with high ductility level
λ md : Cross-section condition limit value for elements with limited ductility level


  • No labels