Design Response Spectrum for Horizontal Earthquake Effects per ASCE 7-16 with ideCAD

Design Response Spectrum for Horizontal Earthquake Effects per ASCE 7-16 with ideCAD

How does ideCAD define design response spectrum, according to ASCE 7-16?


  • By using the parameters determined in Table 12.2-1 and 11.5.1, the Reduced Design Spectral acceleration, Sa is determined automatically according to Section 12.9.1.2.

  • According to the structural system type, using the R, Cd and Ωo coefficients obtained from Table 12.2-1, R/Ie and the reduced design spectral acceleration are calculated automatically.


Symbols

Cd = Deflection amplification factor
Ie= Seismic importance factor
R = Response modification coefficient


The reduced design spectral acceleration Sa, which is the ordinate of the reduced design acceleration spectrum for a given natural vibration period T, used to determine the reduced seismic loads in the horizontal direction, is that of Sa https://idecad.atlassian.net/wiki/spaces/IKP/pages/1126040266, is obtained by dividing the R, https://idecad.atlassian.net/wiki/spaces/IKP/pages/1126466187 and multiply with Ie.

On the Analysis ASCE 7-16 Wizard - Design Spectra tab, the spectral acceleration coefficients obtained from USGB based on the coordinates and the horizontal elastic design spectrum Sa is calculated according to the formula below. https://idecad.atlassian.net/wiki/spaces/IKP/pages/1126040266 is represented by a total of 4 functions, different in each region, and shown in the function below.

  • It’s determined with the equation 11.4-5 from T=0 to T0 .

LaTeX Math Inline

  • It’s equal SDS from T0 to Ts .

  • It’s determined with the equation 11.4-6 from Ts to TL .

LaTeX Math Inline

  • It’s determined with the equation 11.4-7 for periods greater than TL.

LaTeX Math Inline

LaTeX Math Inline

In the Analysis Settings - Response Spectrum Function tab, the horizontal design spectrum is determined and shown using the design spectral response acceleration parameters.

Structural System Type

Response Modification Coefficient, R

Overstrengh Factor, Ωo

Deflection Amplification Factor, Cd

Structural System Limitations Including Structural Height, hn (ft) Limits

Seismic Design Category

B

C

D

E

F

A. Bearing Wall Systems

A1 - Special reinforced concrete shear walls

5

21/2

5

NL

NL

160

160

100

A2 - Ordinary reinforced concrete shear walls

4

21/2

4

NL

NL

NP

NP

NP

A3 - Detailed plain concrete shear walls

2

21/2

2

NL

NP

NP

NP

NP

A4 - Ordinary plain concrete shear walls

11/2

21/2

11/2

NL

NP

NP

NP

NP

B. Building Frame Systems

B1 - Steel eccentrically braced frames

8

2

4

NL

NL

160

160

100

B2 - Steel special concentrically braced frames

6

2

5

NL

NL

160

160

100

B3 - Steel ordinary concentrically braced frames

31/4

2

31/4

NL

NL

35

35

NP

B4 - Special reinforced concrete shear walls

6

21/2

5

NL

NL

160

160

100

B5 - Ordinary reinforced concrete shear walls

5

21/2

41/2

NL

NL

NP

NP

NP

B6 - Detailed plain concrete shear walls

2

21/2

2

NL

NP

NP

NP

NP

B7 - Ordinary plain concrete shear walls

11/2

21/2

11/2

NL

NP

NP

NP

NP

C. Moment-Resisting Frame Systems

C1 - Steel special moment frames

8

3

51/2

NL

NL

NL

NL

NL

C2 - Steel special truss moment frames

7

3

51/2

NL

NL

160

100

NP

C3 - Steel intermediate moment frames

41/2

3

4

NL

NL

35

NP

NP

C4 - Steel ordinary moment frames

31/2

3

3

NL

NL

NP

NP

NP

C5 - Special reinforced concrete moment frames

8

3

51/2

NL

NL

NL

NL

NL

C6 - Intermediate reinforced concrete moment frames

5

3

41/2

NL

NL

NP

NP

NP

C7 - Ordinary reinforced concrete moment frames

3

3

21/2

NL

NP

NP

NP

NP

D. Dual Systems with Special Moment Frames Capable of Resisting at Least 25% of Prescribed Seismic Foces

D1 - Steel eccentrically braced frames

8

21/2

4

NL

NL

NL

NL

NL

D2 - Steel special concentrically braced frames

7

21/2

51/2

NL

NL

NL

NL

NL

D3 - Special reinforced concrete shear walls

7

21/2

51/2

NL

NL

NL

NL

NL

D4 - Ordinary reinforced concrete shear walls

6

21/2

5

NL

NL

NP

NP

NP

E. Dual Systems with Intermediate Moment Frames Capable of Resisting at Least 25% of Prescribed Seismic Foces

E1 - Steel special concentrically braced frames

6

21/2

5

NL

NL

35

NP

NP

E2 - Special reinforced concrete shear walls

61/2

21/2

5

NL

NL

160

100

100

E8 - Ordinary reinforced concrete shear walls

51/2

21/2

41/2

NL

NL

NP

NP

NP

F. Shear Wall-Frame Interactive System with Ordinary Reinforced Concrete Moment Frames And Ordinary Reinforced Concrete Shear Walls

F1 - Shear wall-frame interactive system

41/2

21/2

4

NL

NP

NP

NP

NP

G. Cantilevered Column Systems Detailed to Conform to the Requirement for

G1 - Steel special cantilever column systems

21/2

11/4

21/2

35

35

35

35

35

G2 - Steel ordinary cantilever column systems

11/4

11/4